Power quality treatment
0-
active power filter 400V modular APF
This modular APF active power filter is the rack-mount building block for 400V power-quality correction: rated modules of 25, 50, 75, 100 and 150A connect in unlimited parallel stacks and can later be pulled or added as loads change. The IGBT-based inverter samples distorted current with a DSP controller and injects anti-phase compensation, suppressing 2nd-50th-order harmonics at over 92% correction rate while holding PF 0.99. Hot-swappable power modules and N+1 redundancy keep compensation alive during maintenance, making the unit suited to plants with VFDs, rectifiers and UPS systems.
-
SVG static var generator 400V
This SVG static var generator is the 400V workhorse module of Xi'an Xikai's low-voltage compensator line: models of 10, 15, 30, 50, 75 and 100kvar built for 400V plus or minus 20%, 50/60Hz three-phase systems. Forced-air cooled and rack- or wall-mountable, each module doubles as a standalone power-factor unit or as a building block that parallels without limit into larger plants. It injects reactive current in under 15ms to hold PF 0.99, corrects load unbalance and trips itself safely on over-current, over/under-voltage or overtemperature - a drop-in fix for 400V feeds with welding, lifting and VFD loads.
-
SVG Dynamic Reactive Power Compensator Complete Equipments
1.Rated Voltage:6~35kV
2.Compensation Capacity:0.3~50Mvar
3.XD-dSvG has a variety of operating modes: constant reactive current, constant reactive power, constant bus voltage, constant power factor, and each mode can be set accordingto user's requirements.
4.XD-dSVG not only compensates for fundamental reactive power,but also suppresses low-order harmonics and compensates for imbalance. -
SVG- Static Var Generator
1.Rated Input:400V*(1±20%)
2.Power Grid Frequency:50Hz/60Hz
3.Bi-Dynamic Compensation: Maintains PF 0.99, prevents over/under-compensation.
4.Capacity Efficient: 20-30% less capacity required than SVC
5.Rapid Response: <15ms full response, <50μs dynamic. -
Wall-mounted APF/AHF Active Power/Harmonic Filter
1.Rated Input:400V*(1±20%)
2.Power Grid Frequency:50Hz/60Hz
3.Real-time tracking:
Maintains system power factor at 0.99 through linear, bidirectional (capacitive/inductive) compensation.
4.Active technology:
Prevents resonance/harmonic amplification; efficient even under low-voltage conditions.
5.Modular design:
Wall-mounted -
Rack-mounted APF/AHF Active Power/Harmonic Filter
1.Rated Input:400V*(1±20%)
2.Power Grid Frequency:50Hz/60Hz
3.Real-time tracking: Maintains system power factor at 0.99 through linear, bidirectional (capacitive/inductive) compensation.
4.Active technology: Prevents resonance/harmonic amplification; efficient even under low-voltage conditions.
5.Modular design: Rack-mounted
