Parallel capacitor
0-
capacitors in parallel
1.Rated Voltage:6kV,10kV,35kV.
2.Rated Capacity:1-100Mvar(per bank).
3.The capacitor is mainly consisted of container and device body.
4.The core is consisted of severalelements and insulation parts. The element is rolled, pressed andmade of two aluminum foilsand somepiece of thin dielectric polypropylene films sandwiched betweenthe two aluminum foils. In order to reach the differentdemand of voltage and capacity, the elements in core is connected by someseriesand parallelmethod. The technology of aluminum foiledge folding and protruding weldingare used to reduce the loss and increase the performance of partial discharging. -
capacitors in series and parallel
1.Rated Voltage:6kV,10kV,35kV.
2.Rated Capacity:1-100Mvar(per bank).
3.The capacitor is mainly consisted of container and device body.
4.The core is consisted of severalelements and insulation parts. The element is rolled, pressed andmade of two aluminum foilsand somepiece of thin dielectric polypropylene films sandwiched betweenthe two aluminum foils. In order to reach the differentdemand of voltage and capacity, the elements in core is connected by someseriesand parallelmethod. The technology of aluminum foiledge folding and protruding weldingare used to reduce the loss and increase the performance of partial discharging. -
10KV Film Capacitor
1.Frequency 60Hz.
2.Capacitance Deviation -5%~+10%.
3.Max Current 2.5×In.
Equipped with discharge resistors 4.Integrated with independent over-voltage protection devices.
5.Superior self-healing performance and extended service life.
6.Low-loss factor, dry-type design with leakage-free construction.
7.Equipped with discharge resistors. -
10KV High Voltage Shunt Capacitor Bank
1.Frequency 60Hz.
2.Capacitance Deviation -5%~+10%.
3.Max Current 2.5×In.
Equipped with discharge resistors 4.Integrated with independent over-voltage protection devices.
5.Superior self-healing performance and extended service life.
6.Low-loss factor, dry-type design with leakage-free construction.
7.Equipped with discharge resistors. -
Internal Fuse HV Shunt Capacitor
1.Frequency 60Hz.
2.Capacitance Deviation -5%~+10%.
3.Max Current 2.5×In.
Equipped with discharge resistors 4.Integrated with independent over-voltage protection devices.
5.Superior self-healing performance and extended service life.
6.Low-loss factor, dry-type design with leakage-free construction.
7.Equipped with discharge resistors. -
High Voltage Shunt Capacitor
1.Frequency 60Hz.
2.Capacitance Deviation -5%~+10%.
3.Max Current 2.5×In.
Equipped with discharge resistors 4.Integrated with independent over-voltage protection devices.
5.Superior self-healing performance and extended service life.
6.Low-loss factor, dry-type design with leakage-free construction.
7.Equipped with discharge resistors. -
10KV Shunt Capacitor
1.Frequency 60Hz.
2.Capacitance Deviation -5%~+10%.
3.Max Current 2.5×In.
Equipped with discharge resistors 4.Integrated with independent over-voltage protection devices.
5.Superior self-healing performance and extended service life.
6.Low-loss factor, dry-type design with leakage-free construction.
7.Equipped with discharge resistors. -
Reactive Power Compensation Bank
1.Frequency 60Hz.
2.Capacitance Deviation -5%~+10%.
3.Max Current 2.5×In.
Equipped with discharge resistors 4.Integrated with independent over-voltage protection devices.
5.Superior self-healing performance and extended service life.
6.Low-loss factor, dry-type design with leakage-free construction.
7.Equipped with discharge resistors. -
400V Metallurgical Self-Healing Capacitor
1.Frequency 60Hz.
2.Capacitance Deviation -5%~+10%.
3.Max Current 2.5×In.
Equipped with discharge resistors 4.Integrated with independent over-voltage protection devices.
5.Superior self-healing performance and extended service life.
6.Low-loss factor, dry-type design with leakage-free construction.
7.Equipped with discharge resistors. -
Anti-Harmonic Capacitor for Arc Furnace
1.Frequency 60Hz.
2.Capacitance Deviation -5%~+10%.
3.Max Current 2.5×In.
Equipped with discharge resistors 4.Integrated with independent over-voltage protection devices.
5.Superior self-healing performance and extended service life.
6.Low-loss factor, dry-type design with leakage-free construction.
7.Equipped with discharge resistors. -
Capacitor for Metallurgical Industry
1.Frequency 60Hz.
2.Capacitance Deviation -5%~+10%.
3.Max Current 2.5×In.
Equipped with discharge resistors 4.Integrated with independent over-voltage protection devices.
5.Superior self-healing performance and extended service life.
6.Low-loss factor, dry-type design with leakage-free construction.
7.Equipped with discharge resistors. -
Arc Furnace Compensation Capacitor
1.Frequency 60Hz.
2.Capacitance Deviation -5%~+10%.
3.Max Current 2.5×In.
Equipped with discharge resistors 4.Integrated with independent over-voltage protection devices.
5.Superior self-healing performance and extended service life.
6.Low-loss factor, dry-type design with leakage-free construction.
7.Equipped with discharge resistors.