Parallel capacitor

0
  • BKMJ Series SAF Reactive Compensation Capacitor

    1.Frequency 60Hz.
    2.Capacitance Deviation -5%~+10%.
    3.Max Current 2.5×In.
    Equipped with discharge resistors 4.Integrated with independent over-voltage protection devices.
    5.Superior self-healing performance and extended service life.
    6.Low-loss factor, dry-type design with leakage-free construction.
    7.Equipped with discharge resistors.

  • Submerged Arc Furnace Dedicated Capacitor

    1.Frequency 60Hz.
    2.Capacitance Deviation -5%~+10%.
    3.Max Current 2.5×In.
    Equipped with discharge resistors 4.Integrated with independent over-voltage protection devices.
    5.Superior self-healing performance and extended service life.
    6.Low-loss factor, dry-type design with leakage-free construction.
    7.Equipped with discharge resistors.

  • 0.4kV Submerged Arc Furnace Capacitor

    1.Frequency 60Hz.
    2.Capacitance Deviation -5%~+10%.
    3.Max Current 2.5×In.
    Equipped with discharge resistors 4.Integrated with independent over-voltage protection devices.
    5.Superior self-healing performance and extended service life.
    6.Low-loss factor, dry-type design with leakage-free construction.
    7.Equipped with discharge resistors.

  • Square Capacitor for Reactive Power Compensation

    1.Rated Voltage(Ue):100v~1000v .
    2.Installation Indoor.
    3.Case material Galvanized steel sheet.
    4.Output Range 10~100kvar.
    5.Frequency 50/60Hz.
    6.Connection configuration D, Y, YN, III.
    7.Terminal Block :M6, M8, M10 (According to capacitor power).
    8.Lose tanδ<0.001 (20°C 50Hz).
    9.Temprature -25°C~50°C.
    10.Highest Altitude 2000m.
    11.Capacitor (to wall) pitch ≥50mm.
    12.Capacitance Deviation -5%~+10%.

  • BKMJ Series Self-Healing PFC Capacitor

    1.Rated Voltage(Ue):100v~1000v .
    2.Installation Indoor.
    3.Case material Galvanized steel sheet.
    4.Output Range 10~100kvar.
    5.Frequency 50/60Hz.
    6.Connection configuration D, Y, YN, III.
    7.Terminal Block :M6, M8, M10 (According to capacitor power).
    8.Lose tanδ<0.001 (20°C 50Hz).
    9.Temprature -25°C~50°C.
    10.Highest Altitude 2000m.
    11.Capacitor (to wall) pitch ≥50mm.
    12.Capacitance Deviation -5%~+10%.

  • Power Factor Correction Capacitor

    1.Rated Voltage(Ue):100v~1000v .
    2.Installation Indoor.
    3.Case material Galvanized steel sheet.
    4.Output Range 10~100kvar.
    5.Frequency 50/60Hz.
    6.Connection configuration D, Y, YN, III.
    7.Terminal Block :M6, M8, M10 (According to capacitor power).
    8.Lose tanδ<0.001 (20°C 50Hz).
    9.Temprature -25°C~50°C.
    10.Highest Altitude 2000m.
    11.Capacitor (to wall) pitch ≥50mm.
    12.Capacitance Deviation -5%~+10%.

  • Anti-Harmonic Dry-Type Power Capacitor

    1.Rated Voltage(Ue):100v~1000v .
    2.Installation Indoor.
    3.Case material Galvanized steel sheet.
    4.Output Range 10~100kvar.
    5.Frequency 50/60Hz.
    6.Connection configuration D, Y, YN, III.
    7.Terminal Block :M6, M8, M10 (According to capacitor power).
    8.Lose tanδ<0.001 (20°C 50Hz).
    9.Temprature -25°C~50°C.
    10.Highest Altitude 2000m.
    11.Capacitor (to wall) pitch ≥50mm.
    12.Capacitance Deviation -5%~+10%.

  • 50kvar Square Low Voltage Power Capacitor

    1.Rated Voltage(Ue):100v~1000v .
    2.Installation Indoor.
    3.Case material Galvanized steel sheet.
    4.Output Range 10~100kvar.
    5.Frequency 50/60Hz.
    6.Connection configuration D, Y, YN, III.
    7.Terminal Block :M6, M8, M10 (According to capacitor power).
    8.Lose tanδ<0.001 (20°C 50Hz).
    9.Temprature -25°C~50°C.
    10.Highest Altitude 2000m.
    11.Capacitor (to wall) pitch ≥50mm.
    12.Capacitance Deviation -5%~+10%.

  • 50KVAR Self-healing Capacitor

    1.Rated Voltage(Ue):100v~1000v .
    2.Installation Indoor.
    3.Case material Galvanized steel sheet.
    4.Output Range 10~100kvar.
    5.Frequency 50/60Hz.
    6.Connection configuration D, Y, YN, III.
    7.Terminal Block :M6, M8, M10 (According to capacitor power).
    8.Lose tanδ<0.001 (20°C 50Hz).
    9.Temprature -25°C~50°C.
    10.Highest Altitude 2000m.
    11.Capacitor (to wall) pitch ≥50mm.
    12.Capacitance Deviation -5%~+10%.

  • Metallized Film Capacitor

    1.Rated Voltage(Ue):100v~1000v .
    2.Installation Indoor.
    3.Case material Galvanized steel sheet.
    4.Output Range 10~100kvar.
    5.Frequency 50/60Hz.
    6.Connection configuration D, Y, YN, III.
    7.Terminal Block :M6, M8, M10 (According to capacitor power).
    8.Lose tanδ<0.001 (20°C 50Hz).
    9.Temprature -25°C~50°C.
    10.Highest Altitude 2000m.
    11.Capacitor (to wall) pitch ≥50mm.
    12.Capacitance Deviation -5%~+10%.

  • Low Voltage Shunt Capacitor-square

    1.Rated Voltage(Ue):100v~1000v .
    2.Installation Indoor.
    3.Case material Galvanized steel sheet.
    4.Output Range 10~100kvar.
    5.Frequency 50/60Hz.
    6.Connection configuration D, Y, YN, III.
    7.Terminal Block :M6, M8, M10 (According to capacitor power).
    8.Lose tanδ<0.001 (20°C 50Hz).
    9.Temprature -25°C~50°C.
    10.Highest Altitude 2000m.
    11.Capacitor (to wall) pitch ≥50mm.
    12.Capacitance Deviation -5%~+10%.

  • Industrial Filter Capacitor

    1.Rated Voltage(Ue):250v~525v, up to 2000v.
    2.Frequency:50/60Hz.
    3.Compact design,equipped with grounding bolt.
    4.Potting material: PU resin (soft resin).
    5.Easy installation and wiring.
    6.Small size, Light weight.
    7.Self-healing, Maintenance-free.

46