Products
0-
GW7 High Voltage Disconnect Switch
1.Flip-type blade: Low torque, assembled rod/contact (easy maintenance)
2.Stationary contacts: Fixed w/ external springs (no shunting), operation limiters
3.Contacts: High pressure, self-cleaning, ice-breaking
4.Conductive rods: Monobloc Al alloy (high current/heat dissipation/corrosion resistant)
5.Base: Hot-dip galvanized steel, integral design (anti-settlement, easy install)
6.Drive: Corrosion-proof components (stainless/composite bearings)
7.Earth switch: Counterweight balanced (low force)
8.Contacts: Silver-inlaid Cu (high strength/current, anti-corrosion)
9.rated voltage:max252-1100kv
10.rated current:max6300A -
GW6 High Voltage Disconnect Switch
1.Grading rings on stationary contacts (reduced RI, improved E-field)
2.High-strength Al alloy conductors (lightweight/corrosion-proof)
3.Flexible joints at pivots (easy install)
4.Triple-layer bushings (low-friction/self-lubricating); Stainless/brass levers & shafts (weather-resistant)
5.Sealed drive assembly (sand/ice resistant, harsh-environment rated)
6.Hot-dip galvanized base (corrosion protection, extended lifespan)
7.rated voltage:126-550kv
8.rated current:max 4000A -
GW5 High Voltage Disconnect Switch
1.Hot-dip galvanized steel components
2.Stainless steel transmission system (pins, bushings, joints)
3.Optimized Conductivity
4.Externally compressed stainless contact springs (rust-proof, stable force)
5.Aluminum alloy profile
6.High strength, thermal dissipation, maintenance-free
7.Bent copper plates (easy replacement)
8.Minimal friction travel during switching
9.Optional installation on both base sides
10.rated voltage:72.5-126KV
11.rated current:max 2000A -
GW4 High Voltage Disconnect Switch
1.Hot-dip galvanized steel components
2.Stainless steel transmission system (pins, bushings, joints, bearings)
3.Flexible busbar connections
4.Externally compressed stainless contact springs (anti-rust, stable pressure)
5.Aluminum alloy profile
6.Enhanced heat dissipation, maintenance-free
7.Bent copper plates (easy maintenance)
8.Short friction travel during operation
9.Grading rings + shields at contacts
10.Optimized E-field distribution, reduced RF interference
11.Optional installation on both base sides
12.rated voltage:40.5-252kv
13.rated current:max 6300A -
GN27 High Voltage Disconnect Switch
1.Rated Voltage:40.5kV
2.Rated Current:630,1250A
3.Features swing-contact design (low pressure/wear, high heat dissipation), low operating torque, and high insulation/strength insulators.
4.Mounts horizontally, vertically, or inclined. Options: pollution/high-altitude/voltage indicator types. 5.Compatible with switchgear or standalone (with CS6-2 mechanism) -
GN24 High Voltage Disconnect Switch
1.Rated Voltage:12kV
2.Rated Current:400,630,1000,1250A
3.isolates and transfers live/dead bus circuits under no-load
4.Features integrated earthing switch and through-wall mounting -
GN19 High Voltage Disconnect Switch
1.Rated Voltage:12kV
2.Rated Current:400,630,1000,1250A
3.Operated via manual mechanism.
4.Options include pollution, high-altitude, and voltage indicator types -
GN2 High Voltage Disconnect Switch
1.Rated Voltage:40.5kV
2.Rated Current:400,630,1000,1250,2000A
3.Features an integrated earthing switch 4.through-wall mounting capability -
SVG Dynamic Reactive Power Compensator Complete Equipments
1.Rated Voltage:6~35kV
2.Compensation Capacity:0.3~50Mvar
3.XD-dSvG has a variety of operating modes: constant reactive current, constant reactive power, constant bus voltage, constant power factor, and each mode can be set accordingto user's requirements.
4.XD-dSVG not only compensates for fundamental reactive power,but also suppresses low-order harmonics and compensates for imbalance. -
SVG- Static Var Generator
1.Rated Input:400V*(1±20%)
2.Power Grid Frequency:50Hz/60Hz
3.Bi-Dynamic Compensation: Maintains PF 0.99, prevents over/under-compensation.
4.Capacity Efficient: 20-30% less capacity required than SVC
5.Rapid Response: <15ms full response, <50μs dynamic. -
Wall-mounted APF/AHF Active Power/Harmonic Filter
1.Rated Input:400V*(1±20%)
2.Power Grid Frequency:50Hz/60Hz
3.Real-time tracking:
Maintains system power factor at 0.99 through linear, bidirectional (capacitive/inductive) compensation.
4.Active technology:
Prevents resonance/harmonic amplification; efficient even under low-voltage conditions.
5.Modular design:
Wall-mounted -
Rack-mounted APF/AHF Active Power/Harmonic Filter
1.Rated Input:400V*(1±20%)
2.Power Grid Frequency:50Hz/60Hz
3.Real-time tracking: Maintains system power factor at 0.99 through linear, bidirectional (capacitive/inductive) compensation.
4.Active technology: Prevents resonance/harmonic amplification; efficient even under low-voltage conditions.
5.Modular design: Rack-mounted
