productPic

BGH-40.5 Vacuum Circuit Breaker

1.Rated Voltage:40.5kV
2.Rated Current:630,1250
3.Frequency:50Hz
4.Perfectly integrating circuit breaker, disconnecting switch and grounding switch, making the box-variable cabinet structure simpler and more convenient for maintenance;
5.Equipped with outdoor 35kV box variable, widely used in photovoltaic, wind energy and other new energy power stations;
6.It can be equipped with an additional lightning arrester, charged display and other functions according to the requirements;
  • Fast Delievery
  • Quality Assurance
  • 24/7 Customer Service

Product Introduction

1.BGH-40.5 Vacuum Circuit Breaker: Reliable Protection for Medium-Voltage Grids

The BGH-40.5 Vacuum Circuit Breaker is a cutting-edge solution designed for modern power systems, combining superior performance with unmatched durability. Ideal for industries ranging from renewable energy to heavy manufacturing, this three-station integrated device simplifies substation design while ensuring safety and efficiency. With its compact structure and advanced vacuum interrupter technology, the BGH-40.5 delivers precise fault interruption, making it a trusted choice for 35kV/40.5kV applications worldwide.

2.Technical Specifications

  • Rated Voltage: 40.5kV
  • Rated Current: 630A / 1250A
  • Frequency: 50Hz
  • Design: Integrated circuit breaker, disconnector, and grounding switch
  • Optional Add-ons: Lightning arresters, charged displays, IoT-ready sensors
No. Parameter name Unit Data
1 Rated current А 630/1250
2 Rated frequency Hz 50
3 Rated insulating level 1 min power frequency withstand voltage(effective value) Inter-phase,ground,vacuum break kV 95
Isolation break kV 118
4 Lightning impulse withstand voltage(peak) Inter-phase,ground, vacuum break kV 185
Isolation break kV 215
5 Rated short-circuit breaking current kA 2531.5
6 Standard Operating sequence O-0.3s-CO-180s-CO
7 Rated-short-circuit making current (peak) kA 6380
8 Rated dynamic stability current (peak) kA 6380
9 Rated thermal stability current kA 2531.5
10 Rated thermal stability time S 4
11 Breaking operations of rated short circuit breaking current times 20
12 Circuit resistance uΩ <150
13 Rated operating voltage V -220/~ 220
14 Mechanical endurance (Circuit breaker /isolating switch) times 10000/3000

3.Key Features & Benefits

1. Simplified Grid Architecture

The BGH-40.5 merges three critical functions into one compact unit, reducing cabinet complexity and maintenance time by 30%. Its modular design allows seamless retrofitting into existing switchgear systems.

2. Built for Renewable Energy

Widely used in solar farms and wind stations, this breaker supports fluctuating loads and harsh outdoor conditions. Pre-configured compatibility with 35kV box-type transformers accelerates project timelines.

3. Enhanced Safety & Efficiency

Vacuum interruption technology eliminates SF6 gas, reducing environmental impact and operational costs. The grounding switch ensures zero-voltage conditions during maintenance, protecting technicians in live grid environments.

4. Rugged Industrial Performance

With IP67 protection and anti-vibration design, the BGH-40.5 excels in mining, metallurgy, and chemical plants. Its corrosion-resistant coating withstands extreme humidity and dust.

4.Applications

Be used in a wide range of industries.

 

Industrial Plants

Industrial Plants

Eliminate power factor penalties in CNC machines and assembly lines while handling surge currents up to 100x rated capacity.

Solar/Wind Farms

Substation

Stabilizes substation voltage against harmonics and intermittent generation from renewable inverters.

Commercial Buildings

Commercial Buildings

Retrofit aging systems in hospitals or malls with silent (<45dB), flame-retardant capacitors that meet NFPA 70 fire codes.

 

5.Manufacturing Excellence

Every BGH-40.5 Vacuum Circuit Breaker undergoes 23 rigorous quality checks under ISO 9001 protocols. Our patented contact material ensures 10,000+ mechanical operations without degradation.

6.Why Choose Us?

  • Certifications: IEC 62271,  and GB/T 1984-2014.
  • R&D Leadership: Developed by a team involved in China’s National 863 Program.
  • Global Support: 48-hour technical response, 12-month warranty.
  • Sustainable Innovation: 15% lower energy loss vs. traditional breakers.

Certificate

Certificate

Certificate

7.FAQs

1. Can the BGH-40.5 replace older SF6-based breakers?

Yes! Its compact footprint allows direct retrofitting with minimal modifications.

2. What altitude range does it support?

Rated for up to 3,000 meters—ideal for high-altitude wind farms.

3. How often should maintenance be performed?

Inspect every 5 years under normal conditions; remote monitoring reduces physical checks.

4. Are smart grid integrations possible?

Absolutely. Add voltage sensors or communication modules for real-time data.

8.Contact Us

Email our engineers at xaxd_electric@163.com for tailored configurations.

Trusted by grid operators across 20+ countries, the BGH-40.5 Vacuum Circuit Breaker redefines reliability in medium-voltage applications. Contact us today to optimize your power infrastructure.

9.Factory Show

Factory

Factory

10.Equipment Display

Equipment

11.Application Cases

State Grid systems, power engineering, steel and metallurgy, petrochemicals, rail transportation, energy and water conservancy, construction, environmental protection, and renewable energy sectors

Shanxi Yongchang Group Coal Chemical Project: 10kV Switchgear​​
Shanxi Yongchang Group Coal Chemical Project: 10kV Switchgear
Gansu Jinhui Mining Project: 40.5kV Switchgear​​
Gansu Jinhui Mining Project: 40.5kV Switchgear
AVIC Turkey Project: 10kV Reactive Power Compensation Capacitor Bank​​
AVIC Turkey Project: 10kV Reactive Power Compensation Capacitor Bank
Sekong Coal Mine (Phonesack Group), Laos: Capacitor Banks & Transformers for 22kV Line Compensation​​
Sekong Coal Mine (Phonesack Group), Laos: Capacitor Banks & Transformers for 22kV Line Compensation
Heilongjiang Project: Capacitor Banks (Tower-Type)​​
Heilongjiang Project: Capacitor Banks (Tower-Type)
Xinjiang Project: Capacitor Banks (Tower-Type)​​
Xinjiang Project: Capacitor Banks (Tower-Type)

12.Team and Exhibition

Team and Exhibition

Send