Products
0-
delta capacitor bank
TBBZ type high voltage reactive power automatic compensation device, is suitable for 110kV and 35kV substation, 10kV(6kV or 3kV) bus automatic reactive power tracking compensation. It can achieve reactive power dynamic control and regulation and improve voltage quality and power factor according to the power grid voltage through comprehensive judgment and intelligent automatic switching. It can effectively solve the 10kv(6kV or 3kV) power distribution system reactive power compensation and comprehensive treatment of the problem. It can also meet the need for voltage priority control, and use the capacitor voltage regulation effect to improve the voltage pass rate.It is widely used in metallurgy, iron and steel, petroleum, mining, machinery, building materials, transportation, chemical industry and other industries of the national economy of the power system.
-
delta connected capacitor bank
TBBZ type high voltage reactive power automatic compensation device, is suitable for 110kV and 35kV substation, 10kV(6kV or 3kV) bus automatic reactive power tracking compensation. It can achieve reactive power dynamic control and regulation and improve voltage quality and power factor according to the power grid voltage through comprehensive judgment and intelligent automatic switching. It can effectively solve the 10kv(6kV or 3kV) power distribution system reactive power compensation and comprehensive treatment of the problem. It can also meet the need for voltage priority control, and use the capacitor voltage regulation effect to improve the voltage pass rate.It is widely used in metallurgy, iron and steel, petroleum, mining, machinery, building materials, transportation, chemical industry and other industries of the national economy of the power system.
-
current limiting reactor capacitor bank
1.there is current limiting reactor used for capacitor bank.
2.Normally this types of capacitor bank is used outside with frame type.
3.This types of capacitor bank can do from 6KV to 35KV. -
capacitors banks
1. Automatic compensation load reactive power, improve the load power factor;
2. Reduce network loss, high efficiency and energy saving;
3. Control harmonics of the system or control harmonics according to user requirements;
4. Reduce reactive current, save transformer capacity cost, improve transformer output.
5. Voltage priority control, the voltage regulation function of the capacitor can be used to improve the voltage pass rate. -
automatic power factor correction capacitor bank
1. Automatic compensation load reactive power, improve the load power factor;
2. Reduce network loss, high efficiency and energy saving;
3. Control harmonics of the system or control harmonics according to user requirements;
4. Reduce reactive current, save transformer capacity cost, improve transformer output.
5. Voltage priority control, the voltage regulation function of the capacitor can be used to improve the voltage pass rate. -
auto capacitor bank
1. Automatic compensation load reactive power, improve the load power factor;
2. Reduce network loss, high efficiency and energy saving;
3. Control harmonics of the system or control harmonics according to user requirements;
4. Reduce reactive current, save transformer capacity cost, improve transformer output.
5. Voltage priority control, the voltage regulation function of the capacitor can be used to improve the voltage pass rate. -
ac capacitor bank
1. Automatic compensation load reactive power, improve the load power factor;
2. Reduce network loss, high efficiency and energy saving;
3. Control harmonics of the system or control harmonics according to user requirements;
4. Reduce reactive current, save transformer capacity cost, improve transformer output.
5. Voltage priority control, the voltage regulation function of the capacitor can be used to improve the voltage pass rate. -
transmission capacitor bank
1. Automatic compensation load reactive power, improve the load power factor;
2. Reduce network loss, high efficiency and energy saving;
3. Control harmonics of the system or control harmonics according to user requirements;
4. Reduce reactive current, save transformer capacity cost, improve transformer output.
5. Voltage priority control, the voltage regulation function of the capacitor can be used to improve the voltage pass rate. -
reactor and capacitor bank
1. Automatic compensation load reactive power, improve the load power factor;
2. Reduce network loss, high efficiency and energy saving;
3. Control harmonics of the system or control harmonics according to user requirements;
4. Reduce reactive current, save transformer capacity cost, improve transformer output.
5. Voltage priority control, the voltage regulation function of the capacitor can be used to improve the voltage pass rate. -
substation capacitor banks
1. Automatic compensation load reactive power, improve the load power factor;
2. Reduce network loss, high efficiency and energy saving;
3. Control harmonics of the system or control harmonics according to user requirements;
4. Reduce reactive current, save transformer capacity cost, improve transformer output.
5. Voltage priority control, the voltage regulation function of the capacitor can be used to improve the voltage pass rate. -
lv capacitor banks
1.system voltage:Below AC450.
2.Automatic reactive power compensation to improve power factor.
3.Enhanced equipment efficiency with reduced investment costs.
4.Minimized distribution line losses and transformer losses.
5.Optimized voltage quality and improved power supply reliability.
6.Compatibility: Integrates with global cabinet systems (MNS/GCK/GGD). -
mv capacitor bank
1. The device is allowed to operate for a long time at 1.1 times the rated voltage of the power frequency, in which the peak voltage including all harmonic components should not exceed 1.2√2Un.
2.The capacitor bank allows continuous operation at a steady state overcurrent of 1.3 times the rated.
3. High Voltage Reactive Power Automatic Compensation Device Operation Instructions current due to overvoltage and higher harmonics.
4.The difference between the actual capacitance of the device and its rated capacitance shall not exceed (0~+10) % of the rated value, and the ratio of the maximum capacitance to the minimum capacitance between any two terminals of the device shall not exceed 1.06. ● The device can limit the inrush current generated by the capacitor bank instantaneously to less than 20 times the rated current of the capacitor bank.
