KYN61-40.5 metal-clad switchgear
- Fast Delievery
- Quality Assurance
- 24/7 Customer Service
Product Introduction
KYN61-40.5 metal-clad switchgear for Indoor Power Distribution
For indoor distribution projects, begin with the feeder load, available fault level and site conditions. KYN61-40.5 metal-clad switchgear from Xi'an Xikai Medium & Low Voltage Electric Co., Ltd. combines a withdrawable breaker handcart with separate busbar, cable and low-voltage instrument compartments. Its published ratings cover 40.5kV, multiple current classes and indoor operating conditions. Review the specifications below against your single-line diagram before selecting a configuration. Confirm breaker compatibility, protection settings and any required test documentation during technical review so the proposed assembly matches your project requirements.
Product Specifications
| Parameter | Specification |
|---|---|
| Rated voltage | 40.5kV |
| System | 3-phase AC 50Hz |
| Installation | Indoor |
| Rated currents | 630A, 1250A, 1600A, 2000A and 2500A |
| Rated short-circuit breaking currents | 20kA, 25kA, 31.5kA and 40kA |
| Corresponding peak withstand currents | 50, 63, 80 and 100kA |
| Short-time withstand current | The 4s short-time withstand current matches the breaking current class. |
| Operating altitude | up to 2000m |
| Ambient temperatures | -10°C to +40°C |
| Power-frequency withstand voltage | 95kV for 1 minute (dry) |
| Lightning impulse withstand voltage (BIL) | 185kV |
| Partial discharge (PD) levels | typically <100pC |
| Enclosure protection rating | IP4X |
| Protection rating when the door is open | IP2X |
| Standard cabinet width | 1400mm |
| Circuit breaker types | ZN85, HD4 and LN2-40.5 |
| Standard vacuum circuit breaker | ZN85-40.5 |
| SF6 circuit breaker options | SF1 or HD4 |
| Operating mechanisms | spring and permanent-magnetic |
| Control power | DC 110V/220V or AC 110V/220V |
| Standards | IEC 62271-200, GB/T 11022, DL/T 404-1997, GB 3906 |
| Smart-grid and SCADA integration | IEC 61850 |
| Factory checks | 50+ |
| Mechanical operation test | 50-100 cycles |
The table reproduces the supplied product specifications without adding parameters from application descriptions or company information. Unprovided dimensions, weights and other specifications are not inferred; request the relevant drawings or technical documentation before completing equipment selection.
The partial-discharge figure is stated as typical, not as a guaranteed acceptance limit. Confirm the applicable test conditions, acceptance criteria and standards editions for the proposed configuration.
Construction and Insulation
KYN61-40.5 metal-clad switchgear uses aluminum-zinc coated steel sheets, CNC machining and multi-fold processing. Separate compartments accommodate the busbar, breaker handcart, cables and low-voltage instruments.
The insulation arrangement combines air with heat-shrinkable busbar tubing and epoxy resin contact boxes and bushings. These components form the described composite insulation system.
In the model designation, “K” identifies metal-clad construction, “Y” identifies the removable arrangement and “N” identifies indoor installation. The listed standard cabinet width is 1400mm; obtain the complete arrangement drawing to check room layout, cable entry and maintenance access.
Interlocks, Access and Internal Arc Requirements
The described interlocking arrangement includes mechanical, electrical and programmatic interlocks. It is intended to control switching and access sequences, including handcart movement, earthing-switch operation and entry into live compartments.
A withdrawable breaker handcart provides access for breaker servicing and replacement. It does not, by itself, establish that maintenance can be performed safely without shutdown. Isolation and access procedures must match the work being undertaken.
No specific internal arc classification is supplied here. If your project requires internal arc performance, request the applicable IEC 62271-200 classification and test report for the proposed assembly. Do not assume an arc-resistant rating from the metal-clad construction or the standards listing alone.
Breaker Selection and Monitoring
When specifying KYN61-40.5 metal-clad switchgear, compare the available fault level with the listed breaking-current classes and the feeder load with the rated-current options. The specifications identify ZN85, HD4 and LN2-40.5 breaker types, a standard ZN85-40.5 vacuum breaker, and SF1 or HD4 SF6 options.
Confirm the exact breaker model and operating mechanism as a compatible assembly rather than assuming that every listed option is interchangeable. Your single-line diagram, load schedule and protection requirements provide the basis for configuration review.
Optional monitoring is described for temperature, current and voltage. IEC 61850 is listed for smart-grid and SCADA integration; confirm the required communication functions, devices and interfaces with your control-system requirements.
Testing and Procurement Verification
The specifications list more than 50 factory checks and 50–100 mechanical operating cycles. Request the inspection scope and unit-specific records to establish which checks apply to your order.
A procurement review should cover insulation testing, interlock operation, handcart movement, and primary and secondary connection alignment. Agree the factory acceptance test procedure and acceptance criteria before inspection.
The listed power-frequency withstand and lightning impulse values are product ratings. Their presence in the table does not establish that every unit receives both tests during routine factory inspection. Request the relevant routine-test records and type-test reports, including temperature-rise documentation where required by the project.
Applications and Site Conditions
Potential applications include indoor industrial distribution, power plants, substations, and wind or solar collection and distribution systems. Suitability depends on the selected ratings, protection scheme and operating conditions.
Assess KYN61-40.5 metal-clad switchgear against the specified indoor installation, altitude and ambient-temperature limits. Do not apply ratings from other equipment in the manufacturer's portfolio to this product.
For condensation-prone installations, the described arrangement uses temperature and humidity controllers with internal heaters. Confirm whether these components are included in the proposed configuration and how they will be supplied and controlled.
Manufacturer and Project Coordination
Xi'an Xikai Medium & Low Voltage Electric Co., Ltd. supplies switchgear and related electrical equipment, including transformers, vacuum circuit breakers, instrument transformers and prefabricated substations.
For a coordinated equipment package, identify the interfaces between the switchgear, transformers, protection devices and control system. Request current company certificates and any destination-specific product approvals required by your procurement process.
Configuration, Delivery and Support
Configuration requests may cover busbar materials, breaker brands, protection schemes and communication protocols. Special sealing, finishes, layouts or other environmental adaptations require technical confirmation; they should not be treated as standard features.
Production lead time is quoted after technical confirmation. Export packing, shipping arrangements, drawings, the bill of materials and the delivery schedule should be agreed for the order.
Confirm installation guidance, technical-support availability, warranty coverage and response commitments in the quotation or contract.
Information to Include in Your Inquiry
- Single-line diagram and feeder or load schedule.
- Required voltage, rated current and short-circuit breaking current.
- Preferred breaker, control-power supply and protection requirements.
- Communication and monitoring requirements.
- Installation altitude, ambient conditions and any special environmental needs.
- Switchgear-room layout, cable-entry requirements and available space.
- Required inspection documents, destination approvals and delivery location.
FAQ
Which breaker configuration should I choose?
Use the system fault level and feeder load to identify suitable electrical ratings. Then confirm breaker compatibility, operating mechanism, protection requirements and control power for the proposed assembly.
Does the page confirm an internal arc rating?
No specific internal arc classification is provided. Request the classification and corresponding test report if internal arc performance is a project requirement.
What dimensions are available?
The supplied specifications give a standard cabinet width of 1400mm. Depth, height, weight and installation clearances are not provided and should be obtained from the relevant drawings.
Can the assembly be customized?
The described configurable areas include busbars, breakers, protection and communications. Availability and any changes to drawings, testing or delivery require technical confirmation.
How is lead time established?
Lead time is quoted after the configuration is confirmed. Include your required delivery date and documentation requirements with the initial inquiry.
Contact Us
Email xaxd_electric@163.com for configuration review, drawings and pricing. Include your single-line diagram, required ratings, site conditions and delivery location.
Send Inquiry