productPic

BKGKL Dry-type Air Core Shunt Reactor

1.Connected in parallel in 500 kv,200 kv and 110 kv substation low-voltage side, used for long distance transmission line
2.capacitance reactive compensation, make the transmission and distribution system voltage stability.
  • Fast Delievery
  • Quality Assurance
  • 24/7 Customer Service

Product Introduction

1.BKGKL Dry-type Air Core Shunt Reactor: Powering Stable Grids Worldwide

The BKGKL Dry-type Air Core Shunt Reactor is a cutting-edge solution engineered to optimize voltage stability and reactive power compensation in high-voltage substations. Designed for 500 kV, 200 kV, and 110 kV systems, this reactor minimizes transmission losses and ensures reliable performance across long-distance power networks. Whether you’re upgrading aging infrastructure or integrating renewable energy sources, the BKGKL reactor delivers unmatched efficiency and durability.

2.Technical Specifications

  • Voltage Range: 15 kV to 36 kV
  • Capacity: 50 MVAR to 300 MVAR
  • Impedance Tolerance: ±2% (ensures grid stability)
  • Insulation Class: F/H (withstands up to 155°C–180°C)
  • Energy Loss: <0.05% at rated current
  • Standards: IEC 60076-6, IEEE C57.21, ISO 9001

 

Type

 

System voltage

(KV)

 

Rated terminal voltage

(V)

 

Rated capacity

(KVar)

 

Rated current

(A)

 

Rated inductance

(mH)

External dimensions: Outer diameter D* height H

(mm)

The diameter of the base foot installation

(mm)

 

Weight

(kg)

 

Loss

(KW)

BKGK1-1000/

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5773.5

 

 

 

 

 

 

 

1000

173.2

106.11

φ1500×150(

φ1200

1250

12.4

BKGKL-2000/10

2000

346.4

53.05

φ1700×1550

φ150

1640

18.4

BKGKL-3333/10

3333

577.3

31.83

φ1800×1630

φ1600

2700

24.2

BKGKL-5000/10

5000

866.0

21.22

φ1850×1650

φ1650

3550

30.0

BKGKL-6667/10

6667

1154.8

15.91

φ1950×1650

φ1750

3910

34.7

BKGKL-8000/10

8000

1385.6

13.26

φ2100×1660

φ1900

4300

39.8

BKGKL-10000/10

10000

1732.1

10.61

φ2200×1740

φ2000

4680

42.5

BKGKL-15000/10

15000

2598.1

7.07

φ2400×1800

φ220

5650

52.8

BKGKL-1000/35

 

 

 

 

 

 

35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20207.3

 

 

 

 

 

 

 

 

 

 

1000

49.5

1299.43

φ2350×2400

φ2150

1500

14.1

BKGKL-2000/35

2000

99.0

649.71

φ2350×2380

φ2150

2100

21.7

BKGKL-3333/35

3333

165.0

389.83

φ2300x 240c

φ2100

2730

27.6

BKGKL-5000/35

5000

247.4

259.99

φ2350×2310

φ2050

4100

34.2

BKGKL-6667/35

6667

329.9

194.97

φ2400×2200

φ2200

4420

35.5

BKGKL-8000/35

8000

395.9

16245

φ2450×2300

φ225(

4580

38.6

BKGKL-10000/35

10000

494.9

129.97

φ2550×2330

φ235C

4850

44.6

BKGKL-13333/35

13333

659.8

97.49

φ2600×2400

φ2400

8010

51.2

BKGKL-15000/35

15000

742.3

86.65

φ2700×2450

φ2500

8370

55.9

BKGKL-20000/35

20000

989.7

64.99

φ2800×2400

φ2600

9300

62.5

3.Key Features & Benefits

Overheating Prevention

Aluminum windings with epoxy coating resist corrosion and thermal stress, even in continuous operation.

Low Maintenance Costs

Dry-type design eliminates oil leaks and reduces insulation degradation risks.

Global Compliance

Pre-engineered for regional standards: CE (EU), UL/cUL (North America), GOST-R (CIS).

Custom Configurations

Choose from desert-rated (IP55), seismic-resistant (Zone 4), or IoT-enabled models for real-time monitoring.

Eco-Friendly

SF6-free construction and recyclable materials align with sustainability goals.

4.Real-World Applications

 

Be used in a wide range of industries.

 

Industrial Plants

Industrial Plants

Eliminate power factor penalties in CNC machines and assembly lines while handling surge currents up to 100x rated capacity.

Solar/Wind Farms

Substation

Stabilizes substation voltage against harmonics and intermittent generation from renewable inverters.

Commercial Buildings

Commercial Buildings

Retrofit aging systems in hospitals or malls with silent (<45dB), flame-retardant capacitors that meet NFPA 70 fire codes.

 

5.How It Works?

The BKGKL Dry-type Air Core Shunt Reactor operates by introducing inductive reactance into the power system. This counters capacitive currents caused by long cables or overhead lines, maintaining voltage within safe limits. Its air-core design eliminates magnetic saturation risks, while modular construction allows easy scalability.

6.Manufacturing & Quality Assurance

  • Material Sourcing: Tier-1 aluminum and epoxy resins.
  • Production: Automated winding machines ensure precision.
  • Testing: 100% impedance verification, partial discharge tests (<10 pC).
  • Certifications: ISO 9001, ISO 14001, 3C (China Compulsory Certification).

7.Why Choose Us?

Award-Winning Innovation: Recognized as a “High-Tech Enterprise” in China.

25+ Years of Expertise: Collaborations with global research institutes.

End-to-End Support: From technical design to 24/7 maintenance.

Proven Reliability: Over 10,000 units deployed across 30+ countries.

 

Certificate

Certificate

Certificate

8.FAQs

1. What standards does the BKGKL reactor meet?

It complies with IEC 60076-6, IEEE C57.21.

2. How does it reduce energy losses?

Air-core design minimizes eddy currents, achieving <0.05% loss at full load.

3. Can it withstand coastal environments?

Yes! Our desert-rated IP55 models resist salt mist and dust.

4. What’s the typical lifespan?

30+ years with proper maintenance, thanks to Class F/H insulation.

5. Do you offer IoT integration?

Yes—Smart Series reactors include real-time thermal sensors for predictive maintenance.

9.Contact Us

Upgrade your grid with the BKGKL Dry-type Air Core Shunt Reactor—where innovation meets reliability.

Contact Us: xaxd_electric@163.com

Ask about bulk discounts and 10-year warranties!

10.Factory Show

Factory

Factory

11.Equipment Display

Equipment

12.Application Cases

State Grid systems, power engineering, steel and metallurgy, petrochemicals, rail transportation, energy and water conservancy, construction, environmental protection, and renewable energy sectors

Shanxi Yongchang Group Coal Chemical Project: 10kV Switchgear​​
Shanxi Yongchang Group Coal Chemical Project: 10kV Switchgear
Gansu Jinhui Mining Project: 40.5kV Switchgear​​
Gansu Jinhui Mining Project: 40.5kV Switchgear
AVIC Turkey Project: 10kV Reactive Power Compensation Capacitor Bank​​
AVIC Turkey Project: 10kV Reactive Power Compensation Capacitor Bank
Sekong Coal Mine (Phonesack Group), Laos: Capacitor Banks & Transformers for 22kV Line Compensation​​
Sekong Coal Mine (Phonesack Group), Laos: Capacitor Banks & Transformers for 22kV Line Compensation
Heilongjiang Project: Capacitor Banks (Tower-Type)​​
Heilongjiang Project: Capacitor Banks (Tower-Type)
Xinjiang Project: Capacitor Banks (Tower-Type)​​
Xinjiang Project: Capacitor Banks (Tower-Type)

13.Team and Exhibition

Team and Exhibition

Send