Capacitors

0
  • harmonic filter capacitor bank

    1.Integrated Design: Combines high-voltage switchgear, transformer, and low-voltage switchgear into a complete system. 2.Reliable Protection: Comprehensive high/low-voltage protection ensures safe and reliable operation with minimal maintenance. 3.Space-Saving & Cost-Effective: Compact footprint, reduced investment, short production cycle, and easy mobility. 4.Flexible Configurations: Supports diverse electrical wiring schemes. 5.Robust Structure: 5.1Unique honeycomb-structured double-layer (composite panel) enclosure for enhanced durability, thermal insulation, and ventilation. 5.2High ingress protection (IP) rating. 5.3Material options: Stainless steel soft alloy, aluminum alloy, cold-rolled steel, or color-coated steel.

  • capacitor bank with harmonic filter

    1.Integrated Design: Combines high-voltage switchgear, transformer, and low-voltage switchgear into a complete system.
    2.Reliable Protection: Comprehensive high/low-voltage protection ensures safe and reliable operation with minimal maintenance.
    3.Space-Saving & Cost-Effective: Compact footprint, reduced investment, short production cycle, and easy mobility.
    4.Flexible Configurations: Supports diverse electrical wiring schemes.
    5.Robust Structure:
    5.1Unique honeycomb-structured double-layer (composite panel) enclosure for enhanced durability, thermal insulation, and ventilation.
    5.2High ingress protection (IP) rating.
    5.3Material options: Stainless steel soft alloy, aluminum alloy, cold-rolled steel, or color-coated steel.

  • filter capacitor in power supply

    1.rated voltage:10kv 2.Frequency: 50/60Hz 3.Operating: indoor or outdoor 4.Ambient temperature: -40°C ~ +45°C_x000b_( Freezing field can meet - 45C) 5.Wind load: not exceed 35m/s 6.Altitude: not exceed 2000m 7.Icing thickness: not exceed 10mm 8.Seismic strength: 8 9.Pollution level: III or IV

  • main filter capacitor

    1.rated voltage:10kv.
    2.Frequency: 50/60Hz.
    3.Operating: indoor or outdoor.
    4.Ambient temperature: -40°C ~ +45°C_x000b_( Freezing field can meet - 45C).
    5.Wind load: not exceed 35m/s.
    6.Altitude: not exceed 2000m.
    7.Icing thickness: not exceed 10mm.
    8.Seismic strength: 8.
    9.Pollution level: III or IV.

  • 60 hz filter capacitor

    1.rated voltage:10kv.
    2.Frequency: 50/60Hz.
    3.Operating: indoor or outdoor.
    4.Ambient temperature: -40°C ~ +45°C_x000b_( Freezing field can meet - 45C).
    5.Wind load: not exceed 35m/s.
    6.Altitude: not exceed 2000m.
    7.Icing thickness: not exceed 10mm.
    8.Seismic strength: 8.
    9.Pollution level: III or IV.

  • ac filter capacitors

    1.rated voltage:10kv.
    2.Frequency: 50/60Hz.
    3.Operating: indoor or outdoor.
    4.Ambient temperature: -40°C ~ +45°C_x000b_( Freezing field can meet - 45C).
    5.Wind load: not exceed 35m/s.
    6.Altitude: not exceed 2000m.
    7.Icing thickness: not exceed 10mm.
    8.Seismic strength: 8.
    9.Pollution level: III or IV.

  • capacitor filter

    1.rated voltage:10kv.
    2.Frequency: 50/60Hz.
    3.Operating: indoor or outdoor.
    4.Ambient temperature: -40°C ~ +45°C_x000b_( Freezing field can meet - 45C).
    5.Wind load: not exceed 35m/s.
    6.Altitude: not exceed 2000m.
    7.Icing thickness: not exceed 10mm.
    8.Seismic strength: 8.
    9.Pollution level: III or IV.

  • low voltage filter capacitor

    1.Uses metallized polypropylene film (MKP) as the dielectric. If a localized breakdown occurs, the surrounding metal layer evaporates instantly, restoring insulation and preventing failure.
    2.Encapsulated in epoxy resin or plastic housing, eliminating oil leakage risks and complying with environmental standards.
    3.rated voltage:440V, 480V, 525V, 690V.
    4.Rated Capacity: 5-100kvar(per unit).

  • ac filter capacitor

    1.rated voltage:10kv.
    2.Frequency: 50/60Hz.
    3.Operating: indoor or outdoor.
    4.Ambient temperature: -40°C ~ +45°C_x000b_( Freezing field can meet - 45C).
    5.Wind load: not exceed 35m/s.
    6.Altitude: not exceed 2000m.
    7.Icing thickness: not exceed 10mm.
    8.Seismic strength: 8.
    9.Pollution level: III or IV.

  • BKMJ Series Filter Capacitor

    1.Uses metallized polypropylene film (MKP) as the dielectric. If a localized breakdown occurs, the surrounding metal layer evaporates instantly, restoring insulation and preventing failure.
    2.Encapsulated in epoxy resin or plastic housing, eliminating oil leakage risks and complying with environmental standards.
    3.rated voltage:440V, 480V, 525V, 690V.
    4.Rated Capacity: 5-100kvar(per unit).

  • Self-Healing Low Voltage Filter Capacitor

    1.Uses metallized polypropylene film (MKP) as the dielectric. If a localized breakdown occurs, the surrounding metal layer evaporates instantly, restoring insulation and preventing failure.
    2.Encapsulated in epoxy resin or plastic housing, eliminating oil leakage risks and complying with environmental standards.
    3.rated voltage:440V, 480V, 525V, 690V.
    4.Rated Capacity: 5-100kvar(per unit).

  • Dry-Type Filter Capacitor

    1.Uses metallized polypropylene film (MKP) as the dielectric. If a localized breakdown occurs, the surrounding metal layer evaporates instantly, restoring insulation and preventing failure.
    2.Encapsulated in epoxy resin or plastic housing, eliminating oil leakage risks and complying with environmental standards.
    3.rated voltage:440V, 480V, 525V, 690V.
    4.Rated Capacity: 5-100kvar(per unit).

89