400V Self-healing Capacitor-cylindrical
2.Frequency:50/60Hz.
3.Compact design,equipped with grounding bolt.
4.Potting material: PU resin (soft resin).
5.Easy installation and wiring.
6.Small size, Light weight.
7.Self-healing, Maintenance-free.
- Fast Delievery
- Quality Assurance
- 24/7 Customer Service
Product Introduction
400V Self-healing Capacitor-Cylindrical | Power Quality Solutions
Product Introduction
When your power system demands reliable reactive power compensation, our 400V Self-healing Capacitor-cylindrical delivers exceptional performance. This advanced cylindrical capacitor features metallized polypropylene film dielectric technology, designed specifically for low-voltage applications. You'll benefit from our compact cylindrical design that saves installation space while providing robust power factor correction. Each 400V Self-healing Capacitor-cylindrical unit incorporates integrated safety protection and automatic discharge functionality, ensuring worry-free operation in industrial and commercial environments. We manufacture these capacitors following strict national standards and IEC guidelines, giving you confidence in every installation.
Our cylindrical capacitors represent years of electrical engineering expertise. They're built to handle demanding conditions while maintaining consistent performance. You'll find them ideal for power distribution systems, motor drives, and reactive power compensation applications.
Technical Specifications
| Parameter | Specification |
|---|---|
| Rated Voltage | 400V AC (250V~525V available, up to 2000V) |
| Frequency | 50/60Hz |
| Capacitance Range | Custom configurations available |
| Insulation Level | 3kV |
| Dielectric Loss | <0.0010 (20℃, 50Hz) |
| Operating Temperature | -20°C to +50°C |
| Altitude | Up to 2000m (high-altitude versions up to 4000m) |
| Encapsulation | PU resin (soft resin) - vacuum potted |
| Housing | Cylindrical aluminum shell |
| Discharge Resistor | Permanently connected (voltage drops below 75V within 3 minutes) |
| Standards Compliance | GB/T 12747.1&2-2004, IEC60831-1/2 |
Main Features and Advantages
Superior Self-Healing Technology
Your system stays protected thanks to our advanced self-healing metallized film. When minor breakdowns occur, the capacitor automatically repairs itself without failure. This extends service life significantly.
Compact Cylindrical Design
You'll appreciate the space-saving cylindrical configuration. It's lighter than traditional box-type capacitors and easier to mount in tight spaces. The grounding bolt ensures safe, straightforward installation.
Triple Safety Protection
We've integrated internal protection against over-temperature, over-pressure, and over-current conditions. Each element disconnects safely when reaching end-of-life, protecting your entire system.
Low Loss Performance
Your energy costs stay minimal with our ultra-low dielectric loss design. Heat dissipation is optimized through thermally conductive resin encapsulation.
Maintenance-Free Operation
Once installed, you can forget about it. No oil, no leaks, no periodic maintenance required. Just reliable, continuous power factor correction.
Practical Applications
You'll find our capacitors performing excellently in:
- Industrial Manufacturing Plants - Compensating reactive power from motors and transformers
- Commercial Buildings - Improving power quality in HVAC and lighting systems
- Power Distribution Networks - Reducing line losses and voltage drops
- Renewable Energy Systems - Stabilizing power output from solar and wind installations
- Data Centers - Ensuring clean, efficient power delivery to critical equipment
- Mining Operations - Handling harsh environments and heavy electrical loads
How It Works
Your 400V Self-healing Capacitor-cylindrical operates by storing electrical energy in its metallized polypropylene film dielectric. When connected in parallel with inductive loads, it supplies reactive power locally, reducing the reactive current flowing through your distribution system.
The self-healing mechanism works like this: if a weak point develops in the dielectric, a small arc vaporizes the metallized coating around the fault area. This isolates the defect within milliseconds, and the capacitor continues operating at slightly reduced capacity. You never experience sudden failure.
The vacuum-impregnated PU resin encapsulation eliminates air pockets and moisture, maximizing dielectric strength. Heat generated during operation transfers efficiently through the resin to the aluminum shell, maintaining optimal operating temperature.
Manufacturing Excellence
At Xi'an Xidian Medium and Low Voltage Electrical Co., Ltd., we bring decades of power equipment expertise to every capacitor we produce. Our manufacturing facility employs precision winding equipment and vacuum processing technology to ensure consistent quality.
We've implemented comprehensive quality management systems including ISO9001, ISO14001, and OHSAS18001 certifications. Every capacitor undergoes rigorous testing before leaving our factory - including voltage withstand tests, capacitance accuracy verification, and discharge resistance validation.
Our research and development team continuously improves designs based on real-world feedback. As participants in national technology projects, we integrate the latest materials and manufacturing processes into our production lines.
Why Choose Us
Proven Track Record
Our products serve thousands of installations across power generation, industrial, and infrastructure sectors. You're choosing a supplier trusted throughout China and internationally.
Comprehensive Product Range
Beyond the 400V Self-healing Capacitor-cylindrical, we offer complete power distribution solutions including switchgear, transformers, and circuit breakers rated from 0.4kV to 40.5kV.
Technical Support
You'll receive expert guidance from our engineering team throughout selection, installation, and operation. We help you optimize your power factor correction system for maximum efficiency.
Competitive Advantage
Our registered capital of 30 million RMB and advanced manufacturing capabilities allow us to offer competitive pricing without compromising quality.
Customization Available
Your application might need specific voltage ratings, capacitance values, or mounting configurations. We provide tailored solutions to match your exact requirements.
FAQ
Q: How long do these capacitors typically last?
A: Under normal operating conditions, you can expect 10-15 years of maintenance-free service. The self-healing property significantly extends operational life compared to non-healing types.
Q: Can I use 400V capacitors on a 380V system?
A: Absolutely. The 400V rating provides an appropriate safety margin for 380V networks, which is standard practice in capacitor applications.
Q: What happens if the capacitor overheats?
A: The internal protection device will safely disconnect the affected element from the circuit before any damage occurs to your system.
Q: Do I need external discharge resistors?
A: No. Each unit includes permanently connected discharge resistors that reduce terminal voltage to safe levels within three minutes of disconnection.
Q: Are these suitable for harmonic-rich environments?
A: For systems with significant harmonics, please contact us. We can recommend appropriate detuning reactors or anti-harmonic capacitor configurations.
Q: What's the difference between cylindrical and rectangular capacitors?
A: Cylindrical designs offer better space efficiency and simplified mounting. They're particularly advantageous when you have limited panel depth.
Contact Us
Ready to improve your power quality? Our technical team is here to help you select the perfect capacitor configuration for your application.
Email: serina@xaxd-electric.com
Reach out today for technical specifications, pricing quotations, or application engineering support. We'll respond promptly with expert guidance tailored to your specific power system requirements.
---
Xi'an Xidian Medium and Low Voltage Electrical Co., Ltd. - Your trusted partner for comprehensive power distribution solutions. From high and low voltage switchgear to transformers and capacitors, we deliver quality products backed by professional service.