productPic

Self-healing Capacitor

1.Rated Voltage(Ue):250v~525v, up to 2000v.
2.Frequency:50/60Hz.
3.Compact design,equipped with grounding bolt.
4.Potting material: PU resin (soft resin).
5.Easy installation and wiring.
6.Small size, Light weight.
7.Self-healing, Maintenance-free.
  • Fast Delievery
  • Quality Assurance
  • 24/7 Customer Service

Product Introduction

Self-healing Capacitor

Product Introduction

Are you looking for reliable power quality solutions for your electrical system? Our Self-healing Capacitor offers exceptional performance and reliability for industrial and commercial applications. Manufactured by Xi'an Xidian Medium and Low Voltage Electrical Co., Ltd, these capacitors utilize advanced metallized polypropylene film technology with built-in self-healing capabilities. When you choose our capacitors, you're investing in equipment designed to improve power factor, reduce reactive losses, and enhance overall power quality in your low-voltage distribution networks. Each Self-healing Capacitor features maintenance-free operation and comprehensive safety protection mechanisms.

These capacitors are engineered specifically for power-frequency AC systems. They provide shunt connection capabilities that optimize your electrical infrastructure performance. Our compact design ensures easy integration into existing systems while delivering superior electrical characteristics.

Technical Specifications

Parameter Specification
Rated Voltage (Ue) 250V, 400V, 460V, 480V, 525V, 660V (up to 2000V)
Frequency 50/60 Hz
Insulation Level 3kV
Dielectric Loss <0.0010 (20°C, 50Hz)
Operating Temperature -20°C to +50°C
Altitude Up to 2000m (high-altitude models available up to 4000m)
Encapsulation PU Resin (Soft Resin) / Thermosetting Resin
Housing Material 1mm Galvanized Steel Sheet
Discharge Time Voltage drops below 75V within 3 minutes after power-off
Standards GB/T 12747.1&2-2004, IEC60831-1&2

Main Features and Advantages

Superior Self-healing Technology

Our capacitors feature automatic self-healing properties. When minor dielectric breakdown occurs, the metallized film instantly vaporizes around the fault point, isolating the damaged area without affecting overall performance.

Enhanced Safety Protection

Each capacitor element includes built-in protection devices that monitor over-temperature, over-current, and over-pressure conditions. This patent-protected technology (Patent No. 200810150609.1) ensures your system stays protected.

Compact and Lightweight Design

The space-saving construction reduces installation footprint. You'll find mounting and wiring straightforward with grounding bolts provided.

Excellent Heat Dissipation

Isolation gaps between internal components promote efficient heat transfer. The steel housing facilitates superior thermal management, extending operational lifespan.

Maintenance-Free Operation

Once installed, your Self-healing Capacitor requires no routine maintenance. The permanently connected discharge resistor ensures safe voltage reduction after disconnection.

Low Loss Performance

High-performance metallized polypropylene film minimizes dielectric losses. Internal bronze connections reduce current density and contact resistance, optimizing energy efficiency.

Environmental Resilience

Vacuum processing and thermosetting resin encapsulation completely isolate internal components from external moisture and contaminants.

Practical Applications

Your business can benefit from our capacitors across multiple sectors:

  • Industrial Manufacturing: Improve power factor in production facilities with heavy motor loads
  • Commercial Buildings: Optimize energy efficiency in office complexes and shopping centers
  • Power Distribution Networks: Enhance grid power quality and reduce transmission losses
  • Renewable Energy Systems: Support solar and wind integration with stable reactive power compensation
  • Infrastructure Projects: Railway stations, airports, and transportation hubs requiring reliable power conditioning
  • Metallurgy and Petrochemical: Handle demanding environments in processing plants
  • Urban Construction: Smart city electrical systems and modern infrastructure development

How It Works

The self-healing mechanism operates through sophisticated metallized film technology. When localized overstress occurs in the dielectric layer, the ultra-thin metal coating instantly vaporizes. This creates an insulating zone around the fault point, automatically restoring normal operation.

The vacuum-processed components are sealed in thermosetting resin, creating an impermeable barrier. This protects against environmental factors that typically degrade capacitor performance.

When you connect the capacitor to your AC power system, it provides reactive power compensation. This improves your power factor by offsetting inductive loads from motors and transformers. The result? Reduced electricity costs and improved voltage stability throughout your facility.

The permanently connected discharge resistor ensures safe handling. Within three minutes of disconnection, residual voltage drops below 75V, protecting your maintenance personnel.

Manufacturing Excellence

At Xi'an Xidian Medium and Low Voltage Electrical Co., Ltd, we maintain rigorous quality standards. Our manufacturing facility employs advanced production techniques and strict quality control at every stage.

We've implemented comprehensive management systems including ISO9001 (Quality Management), ISO14001 (Environmental Management), and OHSAS18001 (Occupational Health and Safety). These certifications demonstrate our commitment to excellence.

Our research and development team continuously innovates. As participants in national projects, we integrate cutting-edge technology into our product development. This ensures you receive equipment that meets both current standards and future requirements.

Every capacitor undergoes thorough testing before leaving our facility. From raw material inspection through final product verification, we maintain zero-compromise quality assurance.

Why Choose Us

Comprehensive Product Range

We offer complete power distribution solutions beyond capacitors. Our portfolio includes switchgear, transformers, circuit breakers, and more across 9 categories and over 100 varieties.

Proven Track Record

Our products serve demanding applications nationwide. We've earned recognition as a famous brand in China through consistent performance and reliability.

Technical Expertise

With decades of industry experience, our engineering team provides expert consultation. We help you select the optimal configuration for your specific requirements.

Customization Capability

Need special voltage ratings or configurations? We provide customized solutions tailored to your unique application challenges.

Responsive Support

Our dedicated service team ensures you receive timely assistance. From initial inquiry through installation and beyond, we're here to support your success.

Competitive Value

You'll find our pricing competitive while maintaining uncompromising quality standards. We deliver genuine value for your investment.

FAQ

Q: What makes these capacitors "self-healing"?

A: The metallized film automatically isolates micro-faults by vaporizing the metal coating around damage points, restoring normal operation without manual intervention.

Q: How long do these capacitors typically last?

A: With proper operating conditions, our capacitors provide many years of maintenance-free service. Actual lifespan depends on environmental factors and load characteristics.

Q: Can I use these capacitors in outdoor installations?

A: Our standard models are designed for indoor use. Contact us for outdoor-rated solutions specific to your application.

Q: What voltage rating should I select?

A: Choose a voltage rating matching or slightly exceeding your system voltage. Our team can help you determine the appropriate specification.

Q: Do you offer installation support?

A: Yes, we provide technical guidance for proper installation. Our documentation includes detailed specifications and connection diagrams.

Q: Are replacement parts available?

A: While these capacitors are maintenance-free, we maintain comprehensive spare parts inventory for complete system support.

Q: How quickly can you fulfill orders?

A: Lead times vary based on quantity and specifications. Contact us for current availability and delivery schedules.

Contact Us

Ready to improve your power quality with our advanced capacitor solutions? Our technical specialists are standing by to discuss your requirements.

Email: serina@xaxd-electric.com

Reach out today for product information, technical specifications, pricing, or custom solution development. We respond promptly to all inquiries and look forward to supporting your electrical infrastructure needs.

Let us help you optimize your power distribution system with reliable, high-performance capacitor technology backed by manufacturing excellence and responsive service.

---

Xi'an Xidian Medium and Low Voltage Electrical Co., Ltd - Your trusted partner for comprehensive power distribution solutions.

Send