Self-healing Capacitor-cylindrical
2.Frequency:50/60Hz.
3.Compact design,equipped with grounding bolt.
4.Potting material: PU resin (soft resin).
5.Easy installation and wiring.
6.Small size, Light weight.
7.Self-healing, Maintenance-free.
- Fast Delievery
- Quality Assurance
- 24/7 Customer Service
Product Introduction
Self-healing Capacitor-cylindrical
Product Introduction
Looking for reliable power factor correction in your electrical system? Our Self-healing Capacitor-cylindrical delivers exceptional performance for medium and low voltage applications. This advanced capacitor uses metallized polypropylene film technology with intelligent self-healing properties that automatically isolate faults. You get maintenance-free operation with superior safety features built right in. The cylindrical design offers compact dimensions and lightweight construction, making installation simple and efficient. Whether you're upgrading existing systems or designing new installations, this Self-healing Capacitor-cylindrical provides the reliability your power distribution network demands.
With rated voltages from 250V to 525V (customizable up to 2000V), our capacitor adapts to various industrial and commercial environments. The potting material uses PU resin encapsulation for complete environmental protection. You'll appreciate the grounding bolt design and easy wiring connections that speed up installation time.
Technical Specifications
| Parameter | Specification |
|---|---|
| Rated Voltage (Ue) | 250V ~ 525V (up to 2000V available) |
| Frequency | 50/60 Hz |
| Dielectric Material | Metallized Polypropylene Film |
| Insulation Level | 3kV |
| Loss Factor | <0.0010 (20℃, 50Hz) |
| Operating Temperature | -20°C to 50°C |
| Altitude | Up to 2000m (4000m for high-altitude models) |
| Encapsulation | PU Resin (Soft Resin) |
| Discharge Time | Voltage drops below 75V within 3 minutes |
| Housing Material | 1mm Galvanized Steel |
| Standards | GB/T 12747.1&2-2004, IEC60831-1&2 |
Main Features and Advantages
Self-Healing Technology
When minor breakdowns occur, the metallized film automatically repairs itself. This extends service life significantly compared to traditional capacitors.
Compact Cylindrical Design
Small footprint saves valuable panel space. Lightweight construction reduces structural load requirements.
Triple Safety Protection
Built-in protection against over-temperature, over-current, and over-pressure conditions. Internal fuses isolate failed elements automatically.
Superior Heat Dissipation
The steel shell transfers heat efficiently. Internal isolation gaps between elements improve cooling performance and prevent fault propagation.
Maintenance-Free Operation
No liquid electrolyte means zero leakage risk. Once installed, you can forget about routine maintenance.
Low Loss Design
High-quality materials and precision manufacturing minimize energy waste. Internal bronze connections ensure low contact resistance.
Environmental Protection
Vacuum processing and resin encapsulation completely isolate harmful gases and moisture. Eco-friendly design produces no environmental pollution.
Practical Applications
Your power system can benefit from our cylindrical capacitors in numerous scenarios:
- Industrial Manufacturing Plants – Improve power factor in facilities with heavy motor loads
- Commercial Buildings – Reduce electricity costs and enhance power quality
- Power Distribution Networks – Minimize reactive power loss in substations
- Petrochemical Facilities – Reliable operation in demanding industrial environments
- Railway Systems – Power factor correction for traction power supply
- Mining Operations – Robust performance in harsh conditions
- Water Treatment Plants – Efficient reactive power compensation
- Data Centers – Stable power quality for critical equipment
How It Works
The cylindrical capacitor stores electrical energy in a dielectric field. When connected in shunt configuration across your power system, it generates reactive power locally. This compensates for inductive loads like motors and transformers.
The metallized polypropylene film features a ultra-thin metal coating. If a weak spot develops, localized heating vaporizes the metal layer around the fault. This self-clearing action isolates the damaged area within microseconds. The remaining film continues normal operation.
Internal discharge resistors automatically reduce stored voltage after power disconnection. Within three minutes, voltage drops to safe levels below 75V. This protects maintenance personnel and equipment.
The vacuum encapsulation process embeds elements in thermally conductive resin. This creates a hermetic seal against environmental contamination while efficiently transferring internal heat to the steel housing.
Manufacturing Excellence
At Xi'an Xidian Medium and Low Voltage Electrical Co., Ltd., we manufacture every capacitor with precision and care. Our production facility follows strict quality control protocols.
We source premium metallized polypropylene film from certified suppliers. Each capacitor element undergoes vacuum processing to eliminate air pockets and moisture. The thermosetting resin encapsulation uses materials specifically selected for optimal thermal conductivity.
Our manufacturing system holds ISO9001 quality management certification. We also maintain ISO14001 environmental management and OHSAS18001 occupational health certifications. This demonstrates our commitment to quality, environmental responsibility, and worker safety.
Every finished capacitor passes rigorous testing before shipment. We verify insulation resistance, capacitance accuracy, loss factor, and safety protection functions. Only products meeting our strict standards reach your facility.
Why Choose Us
Comprehensive Product Range
We offer over 100 product varieties across 9 categories and 34 series. From switchgear to transformers, we provide complete power distribution solutions.
Technical Expertise
Our engineering team brings decades of experience in medium and low voltage equipment. We participated in national 863 projects and hold multiple patents.
Customization Capability
Standard products don't always fit unique requirements. We provide tailored solutions matching your specific voltage, current, and environmental needs.
Proven Track Record
Our products earned recognition as famous brand products in China. We serve customers across power, metallurgy, petrochemical, and railway industries.
Nationwide Support
Our sales and service network ensures prompt technical support wherever your projects are located.
Quality Assurance
Triple certification (ISO9001, ISO14001, OHSAS18001) backs our quality promise. All products meet national and international standards.
FAQ
Q: What's the typical lifespan of these capacitors?
A: With proper operating conditions, our Self-healing Capacitor-cylindrical typically operates for 100,000+ hours. The self-healing mechanism significantly extends service life.
Q: Can you customize voltage ratings?
A: Yes, we offer customization up to 2000V based on your requirements. Contact our technical team to discuss your specific needs.
Q: How do I determine the right capacitance value?
A: We recommend conducting a power factor analysis of your system. Our engineers can assist with calculations and product selection.
Q: Do these capacitors work at high altitudes?
A: Standard models operate up to 2000m. We offer high-altitude versions rated for 4000m+ elevations.
Q: What maintenance is required?
A: Minimal maintenance is needed. We recommend periodic visual inspection and connection tightness checks during scheduled downtime.
Q: Are replacement parts available?
A: Yes, we maintain inventory of common replacement components and can ship quickly when needed.
Q: What's the lead time for standard products?
A: Standard configuration products typically ship within 2-3 weeks. Custom orders require 4-6 weeks depending on specifications.
Contact Us
Ready to improve your power system efficiency? Our technical team is here to help you select the perfect capacitor solution.
Email: serina@xaxd-electric.com
Reach out today with your technical specifications and application details. We'll provide expert guidance and competitive quotations promptly. Let Xi'an Xidian Medium and Low Voltage Electrical Co., Ltd. be your trusted partner in power quality improvement.
Send Inquiry