400V Self-healing Capacitor-cylindrical BKMJ0.46-30-3
2.Frequency:50/60Hz
3.Compact design,equipped with grounding bolt
4.Potting material: PU resin (soft resin)
5.Easy installation and wiring
6.Small size, Light weight
7.Self-healing, Maintenance-free
- Fast Delievery
- Quality Assurance
- 24/7 Customer Service
Product Introduction
1.400V Self-healing Capacitor-cylindrical BKMJ0.46-30-3: Reliable Power Correction Simplified
The 400V Self-healing Capacitor-cylindrical BKMJ0.46-30-3 is engineered to optimize energy efficiency in industrial, renewable, and commercial power systems. With its advanced self-healing technology and compact cylindrical design, this capacitor reduces downtime, cuts maintenance costs, and ensures stable reactive power compensation. Whether you’re upgrading machinery or integrating solar farms, it delivers 30kvar capacity at 400V with unmatched reliability.
![]() |
![]() |
![]() |
2.Technical Specifications
| Parameter | Value |
|---|---|
| Rated Voltage | 400V |
| Capacitance | 150μF x 3 |
| Current Rating | 21.7A x 3 |
| Frequency | 50/60Hz |
| Operating Temp | -25°C to +70°C |
| Weight | 5.0kg |
| Dimensions (H) | 242mm |
| Certifications | IEC 60831-1/2, UL 810, CE, RoHS |
| Type | VAC | 50Hz | 60Hz | μF | ФD*H (mm) |
||
| kvar | A | kvar | A | ||||
| 250VAC,50/60HZ | |||||||
| BKMJ0.25-5-3YN | 250 | 5 | Single6.7 | 6 | Single8 | 85*3 | Ф65*165 |
| BKMJ0.25-10-3YN | 250 | 10 | Single13.4 | 12 | Single16 | 169.8*3 | Ф86*165 |
| BKMJ0.25-15-3YN | 250 | 15 | Single20 | 18 | Single24 | 254.6*3 | Ф86*235 |
| BKMJ0.25-20-3YN | 250 | 20 | Single26.7 | 24 | Single32 | 339.6*3 | Ф86*278 |
| BKMJ0.25-25-3YN | 250 | 25 | Single33.4 | 30 | Single40 | 424.4*3 | Ф96*278 |
| BKMJ0.25-30-3YN | 250 | 30 | Single40 | 36 | Single48 | 509.3*3 | Ф106*278 |
| 280VAC,50/60HZ | |||||||
| BKMJ0.28-5-3YN | 280 | 5 | Single6.0 | 6 | Single7.2 | 67.3*3 | Ф65*165 |
| BKMJ0.28-10-3YN | 280 | 10 | Single11.9 | 12 | Single14.3 | 135.4*3 | Ф86*165 |
| BKMJ0.28-15-3YN | 280 | 15 | Single17.9 | 18 | Single21.5 | 203*3 | Ф86*235 |
| BKMJ0.28-20-3YN | 280 | 20 | Single23.8 | 24 | Single28.6 | 270.7*3 | Ф86*278 |
| BKMJ0.28-25-3YN | 280 | 25 | Single29.8 | 30 | Single35.8 | 338.4*3 | Ф96*278 |
| BKMJ0.28-30-3YN | 280 | 30 | Single35.8 | 36 | Single42.9 | 406*3 | Ф106*278 |
| 300VAC,50/60HZ | |||||||
| BKMJ0.3-5-3YN | 300 | 5 | Single5.5 | 6 | Single6.7 | 59*3 | Ф65*165 |
| BKMJ0.3-10-3YN | 300 | 10 | Single11.1 | 12 | Single13.4 | 118*3 | Ф86*165 |
| BKMJ0.3-15-3YN | 300 | 15 | Single16.7 | 18 | Single20 | 177*3 | Ф86*235 |
| BKMJ0.3-20-3YN | 300 | 20 | Single22.2 | 24 | Single26.7 | 235.8*3 | Ф86*278 |
| BKMJ0.3-25-3YN | 300 | 25 | Single27.8 | 30 | Single33.3 | 294.8*3 | Ф96*278 |
| BKMJ0.3-30-3YN | 300 | 30 | Single33.3 | 36 | Single40 | 353.7*3 | Ф106*278 |
| 450VAC,50/60HZ | |||||||
| BKMJ0.45-5-3 | 450 | 5 | 6.5 | 6 | 7.7 | 26.2*3 | Ф65*165 |
| BKMJ0.45-10-3 | 450 | 10 | 12.8 | 12 | 15.4 | 52.4*3 | Ф76*235 |
| BKMJ0.45-15-3 | 450 | 15 | 19.3 | 18 | 23.0 | 78.6*3 | Ф86*235 |
| BKMJ0.45-20-3 | 450 | 20 | 25.7 | 24 | 30.8 | 104.8*3 | Ф86*278 |
| BKMJ0.45-25-3 | 450 | 25 | 32 | 30 | 38.5 | 131*3 | Ф96*278 |
| BKMJ0.45-30-3 | 450 | 30 | 38.5 | 36 | 46.2 | 157.2*3 | Ф106*278 |
| BKMJ0.45-33.4-3 | 450 | 33.4 | 42.9 | 40.1 | 51.5 | 175*3 | Ф116*278 |
| BKMJ0.45-35-3 | 450 | 35 | 44.9 | 42 | 53.9 | 183.4*3 | Ф116*278 |
| BKMJ0.45-40-3 | 450 | 40 | 51.4 | 48 | 61.6 | 209.6*3 | Ф126*278 |
| BKMJ0.45-45-3 | 450 | 45 | 57.8 | 54 | 69.3 | 235.8*3 | Ф136*278 |
| BKMJ0.45-50-3 | 450 | 50 | 64.2 | 60 | 77 | 262*3 | Ф136*278 |
| 480VAC,50/60HZ | |||||||
| BKMJ0.48-5-3 | 480 | 5 | 6 | 6 | 7.2 | 23*3 | Ф65*165 |
| BKMJ0.48-10-3 | 480 | 10 | 12 | 12 | 14.5 | 46*3 | Ф76*235 |
| BKMJ0.48-15-3 | 480 | 15 | 18 | 18 | 21.7 | 69*3 | Ф86*235 |
| BKMJ0.48-20-3 | 480 | 20 | 24 | 24 | 28.9 | 92.1*3 | Ф86*278 |
| BKMJ0.48-25-3 | 480 | 25 | 30 | 30 | 36 | 115.2*3 | Ф96*278 |
| BKMJ0.48-30-3 | 480 | 30 | 36 | 36 | 43.3 | 138.2*3 | Ф106*278 |
| BKMJ0.48-33.4-3 | 480 | 33.4 | 40.2 | 40.1 | 48.3 | 153.8*3 | Ф116*278 |
| BKMJ0.48-35-3 | 480 | 35 | 42 | 42 | 50.5 | 161.2*3 | Ф116*278 |
| BKMJ0.48-40-3 | 480 | 40 | 48.2 | 48 | 57.8 | 184.2*3 | Ф126*278 |
| BKMJ0.48-45-3 | 480 | 45 | 54.2 | 54 | 65 | 207.3*3 | Ф136*278 |
| BKMJ0.48-50-3 | 480 | 50 | 60.2 | 60 | 72.2 | 230.3*3 | Ф136*278 |
| 525VAC,50/60HZ | |||||||
| BKMJ0.525-5-3 | 525 | 5 | 5.5 | 6 | 6.6 | 19.3*3 | Ф65*165 |
| BKMJ0.525-10-3 | 525 | 10 | 11 | 12 | 13.2 | 38.5*3 | Ф76*235 |
| BKMJ0.525-15-3 | 525 | 15 | 16.5 | 18 | 19.8 | 57.8*3 | Ф86*235 |
| BKMJ0.525-20-3 | 525 | 20 | 22 | 24 | 26.4 | 77*3 | Ф86*278 |
| BKMJ0.525-25-3 | 525 | 25 | 27.5 | 30 | 33 | 96.3*3 | Ф96*278 |
| BKMJ0.525-30-3 | 525 | 30 | 33 | 36 | 39.6 | 115.5*3 | Ф106*278 |
| BKMJ0.525-33.4-3 | 525 | 33.4 | 36.7 | 40.1 | 44 | 128.6*3 | Ф116*278 |
| BKMJ0.525-35-3 | 525 | 35 | 38.5 | 42 | 46.2 | 134.8*3 | Ф116*278 |
| BKMJ0.525-40-3 | 525 | 40 | 44 | 48 | 52.8 | 154*3 | Ф126*278 |
| BKMJ0.525-45-3 | 525 | 45 | 49.5 | 54 | 59.4 | 173.3*3 | Ф136*278 |
| BKMJ0.525-50-3 | 525 | 50 | 55 | 60 | 66 | 192.5*3 | Ф136*278 |
3.Features & Benefits
- Self-Healing Technology
- Automatically repairs minor dielectric faults, preventing failures and extending lifespan to over 100,000 operational hours.
- Space-Saving Design
- Compact 242mm height and lightweight construction simplify retrofitting into existing capacitor banks or tight spaces.Energy Efficiency
- Reduces power losses by up to 30% with a dissipation factor below 0.2W/kvar, aligning with EN 50530 and LEED standards.
- Durability in Harsh Conditions
- PU resin potting and IP54-rated casing resist dust, moisture, and vibrations—ideal for solar farms or tropical climates.
- Plug-and-Play Installation
- Pre-equipped with grounding bolts and wall-mount brackets for quick integration into low-voltage distribution systems.
4.Real-World Applications
Be used in a wide range of industries.

Industrial Plants
Eliminate power factor penalties in CNC machines and assembly lines while handling surge currents up to 100x rated capacity.

Substation
Stabilizes substation voltage against harmonics and intermittent generation from renewable inverters.

Commercial Buildings
Retrofit aging systems in hospitals or malls with silent (<45dB), flame-retardant capacitors that meet NFPA 70 fire codes.
5.How It Works?
The capacitor’s metallized polypropylene film layers vaporize localized defects during voltage spikes, creating an insulating barrier within milliseconds. This self-recovery mechanism, combined with a pressure-sensitive disconnector, ensures fail-safe operation even during overloads.
6.Manufacturing & Quality Control
Every 400V Self-healing Capacitor-cylindrical BKMJ0.46-30-3 undergoes:
1. Material Screening: High-purity aluminum electrodes and UV-resistant resin.
2. Precision Winding: Automated tension control for uniform film layering.
3. Rigorous Testing: 72-hour load cycling, impulse voltage checks, and thermal shock trials.
4. Certification Audits: Compliant with IEC, and CCC standards via ISO 9001-certified processes.
7.Why Choose Us?
- 20+ Years Expertise: Developed through China’s 863 Program with 15+ patents.
- Eco-Conscious Production: ISO 14001-certified facilities minimize carbon footprint.
- Custom Solutions: Tailor capacitance or enclosures for dust-heavy (Middle East) or high-humidity (SE Asia) environments.
- Fast Turnarounds: Bulk orders delivered in 4 weeks, backed by a 10-year warranty.



8.FAQs
- Q: How does self-healing improve ROI compared to standard capacitors?
- A: It reduces replacement costs by 60% through 1,000+ self-recovery cycles, ideal for high-uptime industries.
- Q: Can this capacitor work with Huawei/SMA inverters?
- A: Yes—pre-tested for harmonic filtering (<3% THD) and compatibility with major solar inverter brands.
- Q: What’s the maintenance routine?
- A: None required. Just ensure ambient temperatures stay within -25°C to +70°C.
9.Contact Us
Email xaxd_electric@163.com for:
- Custom quotes for bulk orders
- Detailed compliance documentation (CE, KC, CCC)
- Technical drawings and IoT-enabled upgrade options
Upgrade to the 400V Self-healing Capacitor-cylindrical BKMJ0.46-30-3 and experience energy savings that scale with your operations!
10.Factory Show


11.Equipment Display

12.Application Cases
State Grid systems, power engineering, steel and metallurgy, petrochemicals, rail transportation, energy and water conservancy, construction, environmental protection, and renewable energy sectors
13.Team and Exhibition

Send Inquiry



