0-
Outdoor HV Capacitor Compensation Device
1.Rated voltage: 6–10kV.
2.Frequency: 50Hz.
3.Capacity: 100–10,000kVar.
4.Ambient temperature: -25℃ ~+45℃;
5.Reactor options:.
Inrush suppression: 0.1–1% reactance.
5th+ harmonic suppression: 6% reactance.
3rd+ harmonic suppression: 12% reactance. -
22kV Line Compensation Capacitor Bank
1.Integrated Design: Combines high-voltage switchgear, transformer, and low-voltage switchgear into a complete system.
2.Reliable Protection: Comprehensive high/low-voltage protection ensures safe and reliable operation with minimal maintenance.
3.Space-Saving & Cost-Effective: Compact footprint, reduced investment, short production cycle, and easy mobility.
4.Flexible Configurations: Supports diverse electrical wiring schemes.
5.Robust Structure:
5.1Unique honeycomb-structured double-layer (composite panel) enclosure for enhanced durability, thermal insulation, and ventilation.
5.2High ingress protection (IP) rating.
5.3Material options: Stainless steel soft alloy, aluminum alloy, cold-rolled steel, or color-coated steel. -
Distribution Line Reactive Compensation Device
1.Integrated Design: Combines high-voltage switchgear, transformer, and low-voltage switchgear into a complete system.
2.Reliable Protection: Comprehensive high/low-voltage protection ensures safe and reliable operation with minimal maintenance.
3.Space-Saving & Cost-Effective: Compact footprint, reduced investment, short production cycle, and easy mobility.
4.Flexible Configurations: Supports diverse electrical wiring schemes.
5.Robust Structure:
5.1Unique honeycomb-structured double-layer (composite panel) enclosure for enhanced durability, thermal insulation, and ventilation.
5.2High ingress protection (IP) rating.
5.3Material options: Stainless steel soft alloy, aluminum alloy, cold-rolled steel, or color-coated steel. -
10kV Reactive Compensation Panel for Substation
1.Rated voltage: 6–10kV.
2.Frequency: 50Hz.
3.Capacity: 100–10,000kVar.
4.Ambient temperature: -25℃ ~+45℃;
5.Reactor options:.
Inrush suppression: 0.1–1% reactance.
5th+ harmonic suppression: 6% reactance.
3rd+ harmonic suppression: 12% reactance. -
HV Automatic Capacitor Bank Switching Device
1.Rated voltage: 6–10kV.
2.Frequency: 50Hz.
3.Capacity: 100–10,000kVar.
4.Ambient temperature: -25℃ ~+45℃;
5.Reactor options:.
Inrush suppression: 0.1–1% reactance.
5th+ harmonic suppression: 6% reactance.
3rd+ harmonic suppression: 12% reactance. -
TBB10 Series HV Compensation Device
1.Rated voltage: 6–10kV.
2.Frequency: 50Hz.
3.Capacity: 100–10,000kVar.
4.Ambient temperature: -25℃ ~+45℃;
5.Reactor options:.
Inrush suppression: 0.1–1% reactance.
5th+ harmonic suppression: 6% reactance.
3rd+ harmonic suppression: 12% reactance. -
10kV Substation Reactive Power Compensation System
1.Rated voltage: 6–10kV.
2.Frequency: 50Hz.
3.Capacity: 100–10,000kVar.
4.Ambient temperature: -25℃ ~+45℃;
5.Reactor options:.
Inrush suppression: 0.1–1% reactance.
5th+ harmonic suppression: 6% reactance.
3rd+ harmonic suppression: 12% reactance. -
10kV High Volatge Reactive Power Compensation Device
1.Rated voltage: 6–10kV.
2.Frequency: 50Hz.
3.Capacity: 100–10,000kVar.
4.Ambient temperature: -25℃ ~+45℃;
5.Reactor options:.
Inrush suppression: 0.1–1% reactance.
5th+ harmonic suppression: 6% reactance.
3rd+ harmonic suppression: 12% reactance. -
Intelligent Compensation Device with Filtering Function
1.system voltage:Below AC450.
2.Automatic reactive power compensation to improve power factor.
3.Enhanced equipment efficiency with reduced investment costs.
4.Minimized distribution line losses and transformer losses.
5.Optimized voltage quality and improved power supply reliability.
6.Compatibility: Integrates with global cabinet systems (MNS/GCK/GGD). -
10kV Automatic Reactive Compensation Device
1.Rated voltage: 6–10kV.
2.Frequency: 50Hz.
3.Capacity: 100–10,000kVar.
4.Ambient temperature: -25℃ ~+45℃;
5.Reactor options:.
Inrush suppression: 0.1–1% reactance.
5th+ harmonic suppression: 6% reactance.
3rd+ harmonic suppression: 12% reactance. -
LV Automatic Reactive Compensation Panel
1.system voltage:Below AC450.
2.Automatic reactive power compensation to improve power factor.
3.Enhanced equipment efficiency with reduced investment costs.
4.Minimized distribution line losses and transformer losses.
5.Optimized voltage quality and improved power supply reliability.
6.Compatibility: Integrates with global cabinet systems (MNS/GCK/GGD). -
Hybrid Dynamic Compensation Device
1.system voltage:Below AC450.
2.Automatic reactive power compensation to improve power factor.
3.Enhanced equipment efficiency with reduced investment costs.
4.Minimized distribution line losses and transformer losses.
5.Optimized voltage quality and improved power supply reliability.
6.Compatibility: Integrates with global cabinet systems (MNS/GCK/GGD).