Home / Products

Products

0
  • GCS-0.4 Withdrawable Low Voltage Switchgear

    1.Rated Frequency:50,60Hz
    2.Rated Insulation Voltage:660,1000V
    3.High breaking capacity & stability.
    4.Flexible configurations for diverse applications.
    5.Competitive performance against imported alternatives.

  • MNS-0.4 Indoor Withdrawable Low Voltage Switchgear

    1.Rated Voltage:380,660V
    2.Rated Insulation Voltage:660,1000V
    3.Configs: fixed or drawer-type.
    4.Enclosures: steel or thermoplastic. Applications: Land facilities, power plants (conv./nuclear), marine vessels, offshore platforms.
    5.Ambient temperature: -10°C ~ +40°C (temperature can be as low as -25°C during transportation and storage)

  • KYN61-40.5 Removable Metal-Clad Switchgear

    1.Rated Voltage:40.5kV 2.Rated Current:630,1250,1600,2000,2500A 3.Altitude:≤2000m 4.Ambient temperature: -10°C ~ +40°C

  • KYN28-24 Removable Metal-Clad Switchgear

    1.Rated Voltage:24kV 2.Rated Current:630,1250,1600,2000,2500,3150,4000A 3.Five Safety Interlocks (GB3906/IEC298): Prevents load switching errors, live compartment access, and grounding faults. 4.Control & Protection: For power transmission, motor startups, and distribution monitoring. 5.Compatibility: Integrates with NV1-24 vacuum circuit breaker.

  • KYN28-12 Removable Metal-Clad Switchgear

    1.Rated Voltage:12kV
    2.Rated Frequency:50Hz
    3.Five Safety Interlocks: Blocks circuit breaker errors, live compartment access, and grounding faults.
    Applications: Power distribution, motor startups, and grid monitoring.
    Compatibility: ABB VD4, VS1 breakers, isolation trucks, and transformers.

  • AKW Outdoor Frame-type Reactive Power Compensation Device

    1.System voltage: 6kV and above;
    2.Capacity range: 300 kvar to 240 Mvar
    3.Large creepage distance, strong pollution resistance. High mechanical strength and seismic performance.
    Excellent sealing performance.
    4.simple and compact structure, neat wiring, and aesthetically pleasing appearance reduce footprint and installation/maintenance workload.
    5.Ambient temperature: -25℃ ~+45℃;

  • 10kV 22kV outdoor line compensation

    1.Rated Voltage:6kV,10kV,35kV 2.Rated Capacity:1-100Mvar(per bank) 3.Reactive Power Compensation: Offsets lagging reactive power generated by inductive loads (e.g., motors, transformers), improving power factor (typically targeting ≥0.95) 4.Voltage Support: Compensates for voltage drops in long-distance transmission by injecting capacitive reactive power

  • 22kV capacitor bank for outdoor line compensation

    1.Integrated Design: Combines capacitor banks into a complete system.
    2.Reliable Protection: Comprehensive high/low-voltage protection ensures safe and reliable operation with minimal maintenance.
    3.Space-Saving & Cost-Effective: Compact footprint, reduced investment, short production cycle, and easy mobility.
    4.Flexible Configurations: Supports diverse electrical wiring schemes.
    5.Robust Structure:
    5.1Unique honeycomb-structured double-layer (composite panel) enclosure for enhanced durability, thermal insulation, and ventilation.
    5.2High ingress protection (IP) rating.
    5.3Material options: Stainless steel soft alloy, aluminum alloy, cold-rolled steel, or color-coated steel.

  • TBB10 High Voltage Reactive Power Automatic Compensation Device

    1.Rated voltage: 6–10kV
    2.Frequency: 50Hz
    3.Capacity: 100–10,000kVar
    4.Ambient temperature: -25℃ ~+45℃;
    5.Reactor options:
    Inrush suppression: 0.1–1% reactance
    5th+ harmonic suppression: 6% reactance
    3rd+ harmonic suppression: 12% reactance

  • GGJ Low Voltage Reactive Power Intelligent Compensation Device

    1.system voltage:Below AC450
    2.Automatic reactive power compensation to improve power factor
    3.Enhanced equipment efficiency with reduced investment costs
    4.Minimized distribution line losses and transformer losses
    5.Optimized voltage quality and improved power supply reliability
    6.Compatibility: Integrates with global cabinet systems (MNS/GCK/GGD)

  • XKGKL Dry-type Air Core Current Limiting Reactor

    XKGKL series dry-type air-core current limiting reactor in series connection in system line, increase the system impedance,the system failure limit short circuit current, the fault current dropped to permissible value.

  • BKGKL Dry-type Air Core Shunt Reactor

    1.Connected in parallel in 500 kv,200 kv and 110 kv substation low-voltage side, used for long distance transmission line
    2.capacitance reactive compensation, make the transmission and distribution system voltage stability.

72