SVG static var generator 400V

This SVG static var generator is the 400V workhorse module of Xi'an Xikai's low-voltage compensator line: models of 10, 15, 30, 50, 75 and 100kvar built for 400V plus or minus 20%, 50/60Hz three-phase systems. Forced-air cooled and rack- or wall-mountable, each module doubles as a standalone power-factor unit or as a building block that parallels without limit into larger plants. It injects reactive current in under 15ms to hold PF 0.99, corrects load unbalance and trips itself safely on over-current, over/under-voltage or overtemperature - a drop-in fix for 400V feeds with welding, lifting and VFD loads.
  • Fast Delievery
  • Quality Assurance
  • 24/7 Customer Service

Product Introduction

SVG static var generator 400V for Industrial Reactive Power Compensation

Industrial feeders with welding, lifting or variable-frequency drive loads can require changing reactive compensation. The SVG static var generator 400V from Xi'an Xikai Medium & Low Voltage Electric Co., Ltd. offers 10, 15, 30, 50, 75 and 100kvar modules for three-phase systems. It provides linear bidirectional compensation, with full compensation specified at under 15ms and optional three-phase unbalance correction. Rack or wall mounting and forced-air cooling support installation planning. Select the rating from measured feeder demand, and confirm the wiring arrangement, installation requirements and optional functions before ordering.

Product Specifications

Parameter Specification
models 10, 15, 30, 50, 75 and 100kvar
rated input 400V plus or minus 20%
frequency 50/60Hz
networks three-phase three-wire or four-wire
PF 0.99
compensation linear bidirectional compensation
three-phase unbalance correction optional
Full compensation under 15ms
dynamic adjustment under 50 microseconds
cooling Forced-air cooling
enclosure IP20
mounting options rack or wall
parallel operation without limit
communication ports Dual RS485
remote monitoring support GPRS/WiFi
Efficiency at or above 97%
audible noise around 60-65dB
production tests per unit 12+
design life 100,000+ hour

These entries reproduce the supplied Product Specifications without adding parameters from application descriptions, company information or other voltage series. Dimensions, weight, operating temperature limits and warranty terms are not provided in that specification source and have not been inferred. Request the applicable documentation before finalizing your installation.

Compensation for Changing Reactive Demand

Linear bidirectional compensation addresses both inductive and capacitive reactive demand. Unlike fixed-step capacitor switching, the module adjusts its compensation current as demand changes.

The specifications distinguish dynamic adjustment, listed at under 50 microseconds, from full compensation, listed at under 15ms. These figures describe different aspects of response and should not be used interchangeably.

PF 0.99 is the stated specification, not a guarantee for every feeder condition. Request the applicable test conditions and confirm expected performance against your measured load profile.

Three-phase unbalance correction is optional. Confirm its availability for the selected model and wiring configuration, particularly where single-phase loads create uneven phase loading.

Select Capacity from Feeder Measurements

Choose an SVG static var generator 400V using measured reactive demand rather than total load kW alone. The selection review should consider how demand changes during normal operation, peak production and equipment starting.

Provide the following information for a selection discussion:

  • A single-line diagram showing the proposed connection point.
  • System voltage, frequency and three-wire or four-wire arrangement.
  • Power-quality recordings covering representative operating cycles.
  • Measured reactive demand and existing power factor.
  • Details of existing capacitor banks or other compensation equipment.
  • Planned load additions and any requirement for unbalance correction.

Available module ratings are 10, 15, 30, 50, 75 and 100kvar. Any capacity allowance should be justified by the recorded demand and planned changes rather than a fixed percentage applied to every project.

Applications and Suitability

Potential applications include welding cells, cranes, hoists, injection molding machines, elevator banks, battery charging systems and groups of variable-frequency drives. Suitability depends on the measured reactive demand of the connected equipment.

Fast-changing loads may justify converter-based compensation. For steady pump or fan loads, a conventional capacitor bank may be sufficient; compare the options using the actual operating profile.

Reactive compensation should not be presented as a universal remedy for voltage flicker, sags or other power-quality disturbances. Identify the disturbance and its cause before deciding whether this module is an appropriate solution.

Installation and Capacity Expansion

The SVG static var generator 400V supports rack or wall mounting. Obtain the dimensional drawing for the selected rating before allocating cabinet or wall space, and review cooling requirements alongside the stated forced-air cooling and IP20 enclosure.

Modules can operate independently or in parallel. Although the supplied specification lists parallel operation as “without limit,” confirm the proposed module count, control arrangement and installation requirements with the supplier before designing an expanded system.

If continued compensation during servicing is important, request confirmation of how the remaining modules operate when one unit is isolated. Do not assume a particular redundancy arrangement without reviewing the system design.

Protection, Monitoring and Maintenance

The supplied product description lists protection for overload, software and hardware overcurrent, grid over- and under-voltage, power-supply faults, overtemperature, frequency abnormalities and short circuits. Request the selected model’s manual to confirm protection settings, alarm behavior and trip conditions.

Dual RS485 ports and GPRS/WiFi remote monitoring support are listed in the specifications. The product description identifies power factor, compensation current, internal temperature and alarms as available readings. Confirm communication protocols, required accessories and compatibility with your monitoring system before ordering.

Efficiency and audible noise are stated specifications, but measurement conditions are not supplied. The 100,000+ hour design-life figure is not a warranty period or a promise of maintenance-free operation.

Manufacturing Documentation and Supplier Support

Xi'an Xikai Medium & Low Voltage Electric Co., Ltd. supplies electrical equipment and system-integration services. Its portfolio includes switchgear, transformers, circuit breakers, instrument transformers, prefabricated substations and power electronics.

The specifications state 12+ production tests per unit. Request the applicable inspection records or test reports when defining purchase acceptance requirements.

Supplier information lists ISO 9001, ISO 14001 and OHSAS 18001 management certifications, together with 3C certification for low-voltage components. Request current certificates and verify their scope; these claims do not establish separate certification of the complete SVG assembly.

Confirm spare-module availability, technical-support arrangements and warranty terms during quotation review.

FAQ

How do I select the correct module rating?

Use representative feeder measurements to determine compensation demand. Available ratings are 10, 15, 30, 50, 75 and 100kvar. Confirm the proposed selection against load changes and the existing compensation system.

Can I expand an SVG static var generator 400V installation later?

The specifications support parallel operation. Ask the supplier to confirm the expansion arrangement, compatible modules and any control or installation requirements before purchasing additional capacity.

What is the difference between adjustment time and full compensation?

Dynamic adjustment is specified at under 50 microseconds, while full compensation is specified at under 15ms. They are separate response measurements; request supporting conditions if response time is critical to your application.

Is three-phase unbalance correction included?

It is optional. Confirm that it is included in the quotation and supported by the selected model and network configuration.

Which documents should I request before ordering?

Request the selected-module datasheet, dimensional drawing, installation manual, applicable test documentation, relevant certificates and written warranty terms. Confirm any missing information rather than assuming it.