productPic

Line Current Limiting Reactor

XKGKL series dry-type air-core current limiting reactor in series connection in system line, increase the system impedance,the system failure limit short circuit current, the fault current dropped to permissible value.
  • Fast Delievery
  • Quality Assurance
  • 24/7 Customer Service

Product Introduction

Line Current Limiting Reactor - Professional Power System Protection Solutions

Product Introduction

When your electrical system faces the challenge of excessive fault currents, a Line Current Limiting Reactor provides the reliable protection you need. This specialized series-connected inductive device is engineered to limit short-circuit currents in transmission and distribution power networks to safe operational levels. Our XKGKL series dry-type air-core current limiting reactors connect in series with your system lines to increase impedance and effectively reduce fault currents to permissible values.

As power networks expand and new generation sources come online, fault levels naturally rise. Rather than replacing your existing switchgear at enormous cost, installing a Line Current Limiting Reactor allows you to maintain current equipment ratings while ensuring grid stability and protection.

Technical Specifications

Parameter Specification
Rated Voltage 0.4kV - 40.5kV
Rated Current 630A - 4000A
Reactance Tolerance ±3%
Insulation Class F or H
Operating Temperature -50°C to +55°C
Altitude Capability Up to 4000m above sea level
Design Standards IEC 60076-6, IEEE C57.16
BIL Rating Per voltage class requirements
Service Life 30-40 years
Enclosure Type IP23 standard (other ratings available)

Main Features and Advantages

Superior Air-Core Design

Our dry-type air-core construction eliminates fire risks associated with oil-filled units. You get linear inductance characteristics that prevent magnetic saturation even at maximum fault currents.

Exceptional Mechanical Strength

Epoxy-impregnated fiberglass encapsulation withstands massive electrodynamic forces during short circuits, often exceeding 50kA without deformation.

Minimal Maintenance Requirements

Unlike oil-filled alternatives, our reactors require only annual visual inspections. No oil changes, no environmental concerns, just reliable operation.

High Q-Factor Performance

Optimized design minimizes active power losses while maintaining effective current limiting capability.

Environmental Resilience

UV-resistant materials and superior thermal stability ensure dependable performance in harsh outdoor conditions.

Practical Applications

Grid Expansion and Substation Retrofitting

When utilities add transformer capacity or parallel existing units, our reactors manage rising fault levels without requiring expensive switchgear replacement.

Heavy Industrial Power Systems

Steel mills, petrochemical plants, and other energy-intensive facilities use our reactors to protect arc furnaces and VFDs from catastrophic damage while reducing voltage disturbances.

Renewable Energy Integration

At the Point of Common Coupling, our reactors manage fault contributions from wind and solar farms, ensuring Grid Code compliance for harmonic distortion and fault ride-through requirements.

How It Works

Your Line Current Limiting Reactor functions as an impedance buffer in your electrical system. During normal operation, it introduces minimal voltage drop (typically 1-2%). When fault conditions occur, the reactor's inductance limits the rate of current rise, preventing fault currents from exceeding your circuit breakers' interrupting capacity.

The air-core design provides linear response characteristics, meaning the protective function remains consistent regardless of current magnitude. This predictable performance gives you confidence in your system's protection capabilities.

Manufacturing Excellence

At Xi'an Xidian Medium and Low Voltage Electric Co., Ltd., we follow rigorous quality control procedures based on international standards. Our manufacturing process includes:

  • Material verification with conductivity testing of all windings
  • Precision inductance and resistance measurements
  • Comprehensive insulation testing protocols
  • Lightning impulse voltage withstand testing (BIL)
  • Short-time current withstand verification
  • Temperature rise validation testing

Every reactor undergoes these critical tests before shipment, ensuring you receive equipment that meets or exceeds specification requirements.

Why Choose Us

Proven Industry Experience

With expertise spanning medium and low voltage power distribution, we understand your system integration challenges.

Comprehensive Product Range

Our 9 product categories and 34 series offer complete solutions for your electrical infrastructure needs.

Quality Certifications

ISO9001, ISO14001, and OHSAS18001 certifications demonstrate our commitment to quality, environmental responsibility, and safety.

Technical Support

Our engineering team provides detailed magnetic clearance diagrams and customized mounting solutions for your specific installation requirements.

Seismic Compliance

Reinforced designs meet high seismic zone requirements with shake-table tested mounting systems.

FAQ

Q: Will the reactor affect my normal system voltage?

A: The voltage drop during normal operation is minimal, typically 1-2%. We can provide adjustable taps if your load profile changes.

Q: What maintenance does the reactor require?

A: Annual visual inspections and cleaning of support insulators. No oil changes or complex servicing needed.

Q: How do you handle magnetic field concerns?

A: We provide detailed clearance requirements and can design custom solutions to minimize magnetic field impact on surrounding equipment.

Q: What's the expected service life?

A: Our reactors are designed for 30-40 years of reliable operation with minimal maintenance.

Q: Can you customize for specific fault current levels?

A: Yes, we calculate specific reactance values to meet your exact fault current limiting requirements.

Contact Us

Ready to enhance your power system protection? Our technical team is here to help you select the right current limiting solution for your application.

Email: serina@xaxd-electric.com

Contact us today for detailed specifications, custom engineering support, or to discuss your specific Line Current Limiting Reactor requirements. We're committed to providing you with reliable, cost-effective protection solutions that keep your electrical systems operating safely and efficiently.