Outdoor disconnect switch

0
  • GW4 High Voltage Disconnect Switch

    1.Hot-dip galvanized steel components
    2.Stainless steel transmission system (pins, bushings, joints, bearings)
    3.Flexible busbar connections
    4.Externally compressed stainless contact springs (anti-rust, stable pressure)
    5.Aluminum alloy profile
    6.Enhanced heat dissipation, maintenance-free
    7.Bent copper plates (easy maintenance)
    8.Short friction travel during operation
    9.Grading rings + shields at contacts
    10.Optimized E-field distribution, reduced RF interference
    11.Optional installation on both base sides
    12.rated voltage:40.5-252kv
    13.rated current:max 6300A

  • GW10 High Voltage Disconnect Switch

    1.Hot-dip galvanized steel components
    2.Stainless steel transmission system (pins, bushings, joints, bearings)
    3.Flexible busbar connections
    4.Externally compressed stainless contact springs (anti-rust, stable pressure)
    5.Aluminum alloy profile
    6.Enhanced heat dissipation, maintenance-free
    7.Bent copper plates (easy maintenance)
    8.Short friction travel during operation
    9.Grading rings + shields at contacts
    10.Optimized E-field distribution, reduced RF interference
    11.Optional installation on both base sides
    12.rated voltage:126-550kv
    13.rated current:max 5000A

  • GW7 High Voltage Disconnect Switch

    1.Flip-type blade: Low torque, assembled rod/contact (easy maintenance)
    2.Stationary contacts: Fixed w/ external springs (no shunting), operation limiters
    3.Contacts: High pressure, self-cleaning, ice-breaking
    4.Conductive rods: Monobloc Al alloy (high current/heat dissipation/corrosion resistant)
    5.Base: Hot-dip galvanized steel, integral design (anti-settlement, easy install)
    6.Drive: Corrosion-proof components (stainless/composite bearings)
    7.Earth switch: Counterweight balanced (low force)
    8.Contacts: Silver-inlaid Cu (high strength/current, anti-corrosion)
    9.rated voltage:max252-1100kv
    10.rated current:max6300A

  • GW6 High Voltage Disconnect Switch

    1.Grading rings on stationary contacts (reduced RI, improved E-field)
    2.High-strength Al alloy conductors (lightweight/corrosion-proof)
    3.Flexible joints at pivots (easy install)
    4.Triple-layer bushings (low-friction/self-lubricating); Stainless/brass levers & shafts (weather-resistant)
    5.Sealed drive assembly (sand/ice resistant, harsh-environment rated)
    6.Hot-dip galvanized base (corrosion protection, extended lifespan)
    7.rated voltage:126-550kv
    8.rated current:max 4000A

  • GW5 High Voltage Disconnect Switch

    1.Hot-dip galvanized steel components
    2.Stainless steel transmission system (pins, bushings, joints)
    3.Optimized Conductivity
    4.Externally compressed stainless contact springs (rust-proof, stable force)
    5.Aluminum alloy profile
    6.High strength, thermal dissipation, maintenance-free
    7.Bent copper plates (easy replacement)
    8.Minimal friction travel during switching
    9.Optional installation on both base sides
    10.rated voltage:72.5-126KV
    11.rated current:max 2000A

  • GW11 High Voltage Disconnect Switch

    1.Light, strong, corrosion-resistant aluminum alloy conductors.
    2.Simple, easy-install flexible joints.
    3.Low-force, reliable self-lubricating bushings; durable stainless/copper levers/shafts.
    4.Enclosed transmission minimizes environmental impact.
    5.Hot-dip galvanized base extends life, improves appearance.
    6.Modular shared-contact design (252-420kV) saves ~30% space, reduces cost, enables combinations.
    7.rated voltage:126-800kv
    8.rated current:max 5000A