  • HV Capacitor Compensation Complete Set

    1.Rated voltage: 6–10kV.
    2.Frequency: 50Hz.
    3.Capacity: 100–10,000kVar.
    4.Ambient temperature: -25℃ ~+45℃;
    5.Reactor options:.
    Inrush suppression: 0.1–1% reactance.
    5th+ harmonic suppression: 6% reactance.
    3rd+ harmonic suppression: 12% reactance.

  • Air Core Current Limiting Reactor

    XKGKL series dry-type air-core current limiting reactor in series connection in system line, increase the system impedance,the system failure limit short circuit current, the fault current dropped to permissible value.

  • Y10W-102/266W Lightning Arrester Porcelain housed MOA for AC system

    1.Rated Voltage:102kV
    2.unit number:1
    3.DC reference voltage:≥148kV
    4.Creepage Distance:25/31
    5.The lightning arrester has superior protective performance,reliable sealing performance,satisfactory ageing performance,safe pressure relirf capability and uninterrupted innovation in Hi-tech product development.

  • 35kV Oil-immersed Power/Distribution Transformer

    1.Input voltage:35kV,Output voltage:10.5/6.3/3.15kV
    2.Frequency:50/60Hz
    3.Capacity:800~31500kva
    4.Rated voltage:35kV
    5.Winding material:copper\Aluminum
    6.Taping range of HV:±5%
    7. Features S9 (off-circuit tap changer) and SZ9 (on-load tap changer) models.

  • LW25 Outdoor Porcelain Type SF6 Circuit Breaker

    1.Rated Voltage:126/145kV
    2.Rated frequency:50Hz
    3.Rated Normal Current:2000,3150,4000A
    4. Spring: Electric motor charges closing spring; self-charges opening spring during closure.
    5.Hydraulic: Disc spring energy storage (no nitrogen) with hydraulic actuation.
    6.Pneumatic: Compressed-air opening / spring closing.

  • GW4 High Voltage Disconnect Switch

    1.Hot-dip galvanized steel components
    2.Stainless steel transmission system (pins, bushings, joints, bearings)
    3.Flexible busbar connections
    4.Externally compressed stainless contact springs (anti-rust, stable pressure)
    5.Aluminum alloy profile
    6.Enhanced heat dissipation, maintenance-free
    7.Bent copper plates (easy maintenance)
    8.Short friction travel during operation
    9.Grading rings + shields at contacts
    10.Optimized E-field distribution, reduced RF interference
    11.Optional installation on both base sides
    12.rated voltage:40.5-252kv
    13.rated current:max 6300A

  • KYN61-40.5 Removable Metal-Clad Switchgear

    1.Rated Voltage:40.5kV 2.Rated Current:630,1250,1600,2000,2500A 3.Altitude:≤2000m 4.Ambient temperature: -10°C ~ +40°C

  • 10KV High voltage Shunt High-Voltage Capacitors

    1.Rated Voltage:6kV,10kV,35kV
    2.Rated Capacity:1-100Mvar(per bank)
    3.The capacitor is mainly consisted of container and device body.
    4.The core is consisted of severalelements and insulation parts. The element is rolled, pressed andmade of two aluminum foilsand somepiece of thin dielectric polypropylene films sandwiched betweenthe two aluminum foils. In order to reach the differentdemand of voltage and capacity, the elements in core is connected by someseriesand parallelmethod. The technology of aluminum foiledge folding and protruding weldingare used to reduce the loss and increase the performance of partial discharging.

  • active power filter 400V modular APF

    This modular APF active power filter is the rack-mount building block for 400V power-quality correction: rated modules of 25, 50, 75, 100 and 150A connect in unlimited parallel stacks and can later be pulled or added as loads change. The IGBT-based inverter samples distorted current with a DSP controller and injects anti-phase compensation, suppressing 2nd-50th-order harmonics at over 92% correction rate while holding PF 0.99. Hot-swappable power modules and N+1 redundancy keep compensation alive during maintenance, making the unit suited to plants with VFDs, rectifiers and UPS systems.

  • SVG static var generator 400V

    This SVG static var generator is the 400V workhorse module of Xi'an Xikai's low-voltage compensator line: models of 10, 15, 30, 50, 75 and 100kvar built for 400V plus or minus 20%, 50/60Hz three-phase systems. Forced-air cooled and rack- or wall-mountable, each module doubles as a standalone power-factor unit or as a building block that parallels without limit into larger plants. It injects reactive current in under 15ms to hold PF 0.99, corrects load unbalance and trips itself safely on over-current, over/under-voltage or overtemperature - a drop-in fix for 400V feeds with welding, lifting and VFD loads.

  • KYN61-40.5 metal-clad switchgear

    The KYN61-40.5 removable metal-clad switchgear is a 40.5kV indoor switchgear built to IEC 62271-200, GB/T 11022 and DL/T 404-1997, designed for reliable power distribution in industrial plants, substations and renewable energy projects. It covers rated currents of 630A to 2500A with short-circuit breaking capacities of 20/25/31.5/40kA, and operates at altitudes up to 2000m between -10°C and +40°C. The withdrawable breaker trolley, arc-resistant construction and optional IoT monitoring make it a practical choice for 35kV-class networks.

  • 123123

    electrical switchgear types static var compensators svcs unit for reactive power transformers electric transformer for electricity static var compensator 3 phase transformer 3 phase isolation transformer disconnector switch substation isolator 33kv 11kv transformer aluminium transformer transformer pole type about step down transformer 2 kvar capacitor substation components 3phase transformers power factor correction transformer

334