  • High voltage Single Phase Filter Capacitor

    1.Equipped with discharge resistors
    2.New structures and new technology, high reliability.
    3.Low noise, high resistance to overload ability, electric property have reached the international advanced level.
    4.With the international advanced technology of internal fuses, ensure product operation reliability.
    Improved the connection method of discharge resistance and solved the over-voltage problem of series section.
    5.No leakage, new type of bushings automatic argon arc welding tanks.

  • 50KVAR Self-healing Capacitor for PFC(Power factor correction)-square BKMJ

    1.Rated Voltage(Ue):100v~1000v
    2.Installation Indoor
    3.Case material Galvanized steel sheet
    4.Output Range 10~100kvar
    5.Frequency 50/60Hz
    6.Connection configuration D, Y, YN, III
    7.Terminal Block :M6, M8, M10 (According to capacitor power)
    8.Lose tanδ<0.001 (20°C 50Hz)
    9.Temprature -25°C~50°C
    10.Highest Altitude 2000m
    11.Capacitor (to wall) pitch ≥50mm
    12.Capacitance Deviation -5%~+10%

  • 69 72.5kV Capacitive Voltage Transformer

    1.High electric strength. Wide insulation marginHigh-quality medium and new structure design application and advanced technology, the electric strength of CVT is improved obviously, guarantee the product operation reliability effectively.
    2.Long creepage distance. Strong pollution resistance
    3.High mechanical strength capacitor insulator and optimized structure design, it improves product mechanicalstrength.
    4.Good transient response
    Damping optimu design, the CVT transient response to 3pTl level, the residual voltage is less than 2%. Can betteradapt to requirements of fast relay.
    5.Small dielectric loss products.

  • 35kV Outdoor Voltage Transformer(Potential transformer)

    1.Input voltage:35kV,Output voltage:10kV
    2.Frequency:50/60Hz
    3.Rated primary current:600/800A
    4.Limited output(VA):5 or 1A
    5.Standard:GB 20840.2-2014/IEC 61869-1 & 61869-2
    6.The transformer is epoxy resin cast fully-enclosed electromagnetic.It features high accuracy, large capacity, and stable performance.

  • BGH Vacuum Circuit Breaker

    1.Rated Voltage:12kV
    2.Frequency:50Hz
    3.Rated Current:630,1250A
    4.Applicable to industrial and mining, community, enterprise, power plant and other places to meet its control and protection purposes.
    5.Adopting modularized spring-operated mechanism, with superior performance and higher service life.

  • ZN85 Indoor Vacuum Circuit Breaker

    1.Rated Voltage:40.5kV
    2.Rated Frequency:50Hz
    3.Temperature: Ambient air: -15°C to +40°C; Daily average: ≤35°C
    4.Humidity: Daily average relative humidity ≤95% (vapor pressure ≤2.2kPa); Monthly average relative humidity ≤90% (vapor pressure ≤1.8kPa)
    5.Altitude: ≤1000m
    6.Air Quality: No visible dust, smoke, corrosive/combustible gases, vapors, or salt spray

  • GW11 High Voltage Disconnect Switch

    1.Light, strong, corrosion-resistant aluminum alloy conductors.
    2.Simple, easy-install flexible joints.
    3.Low-force, reliable self-lubricating bushings; durable stainless/copper levers/shafts.
    4.Enclosed transmission minimizes environmental impact.
    5.Hot-dip galvanized base extends life, improves appearance.
    6.Modular shared-contact design (252-420kV) saves ~30% space, reduces cost, enables combinations.
    7.rated voltage:126-800kv
    8.rated current:max 5000A

  • BKMJ0.4KV Submerged Arc Furnace Capacitor

    1.Frequency 60Hz
    2.Capacitance Deviation -5%~+10%
    3.Max Current 2.5×In
    Equipped with discharge resistors
    4.Integrated with independent over-voltage protection devices
    5.Superior self-healing performance and extended service life
    6.Low-loss factor, dry-type design with leakage-free construction
    7.Equipped with discharge resistors

  • 400V Self-healing Capacitor-cylindrical BKMJ0.46-30-3

    1.Rated Voltage(Ue):250v~525v, up to 2000v
    2.Frequency:50/60Hz
    3.Compact design,equipped with grounding bolt
    4.Potting material: PU resin (soft resin)
    5.Easy installation and wiring
    6.Small size, Light weight
    7.Self-healing, Maintenance-free

  • ZN63-VS1 Indoor Vacuum Circuit Breaker

    1.Rated Current:630/1250/1600//2000/2500/3150A
    2.Rated Frequency:50Hz
    3.Temperature: -15℃ to +40℃
    4.Humidity:Daily average: ≤95% RH (≤2.2 kPa vapor pressure);Monthly average: ≤90% RH (≤1.8 kPa vapor pressure)
    5.Altitude: ≤1000m
    6.Seismic: ≤ MSK-8 intensity
    7.Air Quality: No significant dust, smoke, corrosive/flammable gases, vapors, or salt spray