CT and PT
0-
123123
electrical switchgear types static var compensators svcs unit for reactive power transformers electric transformer for electricity static var compensator 3 phase transformer 3 phase isolation transformer disconnector switch substation isolator 33kv 11kv transformer aluminium transformer transformer pole type about step down transformer 2 kvar capacitor substation components 3phase transformers power factor correction transformer
-
110KV Capacitive Voltage Transformer
1.High electric strength. Wide insulation marginHigh-quality medium and new structure design application and advanced technology, the electric strength of CVT is improved obviously, guarantee the product operation reliability effectively.
2.Long creepage distance. Strong pollution resistance
3.High mechanical strength capacitor insulator and optimized structure design, it improves product mechanicalstrength.
4.Good transient response Damping optimu design, the CVT transient response to 3pTl level, the residual voltage is less than 2%. Can betteradapt to requirements of fast relay.
5.Small dielectric loss products. -
35kV Indoor Voltage Transformer(Potential transformer)
1.Input voltage:35kV,Output voltage:10kV
2.Frequency:50/60Hz
3.Rated primary current:600/800A
4.Limited output(VA):5 or 1A
5.Standrd:GB 20840.2-2014/IEC 61869-1 & 61869-2
6.The transformer is epoxy resin cast fully-enclosed electromagnetic.It features high accuracy, large capacity, and stable performance. -
24kV Indoor Voltage Transformer(Potential transformer)
1.Input voltage:24kV,Output voltage:480kV
2.Frequency:50/60Hz
3.Rated secondary output:30/80/200VA
4.Rated insulation level:17.5/55/105kV
5.Standard:GB 20840.2-2014/IEC 61869-1 & 61869-2
6.The transformer is epoxy resin cast fully-enclosed electromagnetic.It features high accuracy, large capacity, and stable performance. -
10kV Outdoor/Indoor Voltage Transformer(Potential transformer)
1.Input voltage:10kV,Output voltage:400kV
2.Frequency:50/60Hz
3.Rated insulation level:12/42/75kV
4.Standard:GB 20840.2-2014/IEC 61869-1 & 61869-2
5.The transformer is epoxy resin cast fully-enclosed electromagnetic.It features high accuracy, large capacity, and stable performance. -
Oil-immersed Current Transformer
1.Input voltage:110,35,66kV,Output voltage:11kV
2.Frequency:50Hz
3.Power frequency withstand voltage:230/510/680kV
4.Rated primary current:4000A
5.Standard:GB 20840.2-2014/IEC 61869-1 & 61869-2
6.The transformer is epoxy resin cast fully-enclosed electromagnetic.It features high accuracy, large capacity, and stable performance. -
Zero Sequence Current Transformer
1.Input voltage:11kV,Output voltage:400V
2.Frequency:50/60Hz
3.Rated primary current:20~1000A
4.Rated secondary current:5 or 1A
5.Standard:GB 20840.2-2014/IEC 61869-1 & 61869-2
6.The transformer is epoxy resin cast fully-enclosed electromagnetic.It features high accuracy, large capacity, and stable performance. -
35kV Outdoor Current Transformer
1.Input voltage:35kV,Output voltage:10kV
2.Frequency:50/60Hz
3.Rated primary current:600/800A
4.Limited output(VA):5 or 1A
5.Standard:GB 20840.2-2014/IEC 61869-1 & 61869-2
6.The transformer is epoxy resin cast fully-enclosed electromagnetic.It features high accuracy, large capacity, and stable performance. -
35kV Indoor Current Transformer
1.Input voltage:35kV,Output voltage:10kV
2.Frequency:50/60Hz
3.Rated primary current:20~2500A
4.Rated secondary current:5 or 1A
5.Standard:GB 20840.2-2014/IEC 61869-1 & 61869-2
6.The transformer is epoxy resin cast fully-enclosed electromagnetic.It features high accuracy, large capacity, and stable performance. -
24kV Indoor Current Transformer
1.Input voltage:24kV,Output voltage:10kV
2.Frequency:50/60Hz
3.Rated primary current:20~3150A
4.Rated secondary current:5 or 1A
5.Standard:GB 20840.2-2014/IEC 61869-1 & 61869-2
6.The transformer is epoxy resin cast fully-enclosed electromagnetic.It features high accuracy, large capacity, and stable performance. -
10kV Outdoor/Indoor Current Transformer
1.Input voltage:11kV,Output voltage:10kV
2.Frequency:50/60Hz
3.Rated primary current:20~1000A
4.Rated secondary current:5 or 1A
5.Standard:GB 20840.2-2014/IEC 61869-1 & 61869-2
6.The transformer is epoxy resin cast fully-enclosed electromagnetic.It features high accuracy, large capacity, and stable performance. -
69 72.5kV Capacitive Voltage Transformer
1.High electric strength. Wide insulation marginHigh-quality medium and new structure design application and advanced technology, the electric strength of CVT is improved obviously, guarantee the product operation reliability effectively.
2.Long creepage distance. Strong pollution resistance
3.High mechanical strength capacitor insulator and optimized structure design, it improves product mechanicalstrength.
4.Good transient response
Damping optimu design, the CVT transient response to 3pTl level, the residual voltage is less than 2%. Can betteradapt to requirements of fast relay.
5.Small dielectric loss products.