Iron core reactor

0
  • Low Voltage Reactor

    7% reactance rate: Suppresses harmonics above the 5th order;
    14% reactance rate: Suppresses harmonics above the 3rd order.
    27% reactance rate: Suppresses harmonics above the 2nd order.
    1.Available in three-phase and single-phase dry-type iron-core configurations.
    2.Core: Imported cold-rolled silicon steel laminations segmented by epoxy-laminated glass spacers to stabilize air gaps.
    3.Windings: Tightly wound with Class H/C enamel-coated flat copper wire for high-temperature resistance and silent operation.
    4.Assembly: Non-magnetic fasteners; pre-baked, vacuum-impregnated, and thermally cured to bond core and windings, ensuring low losses and high harmonic suppression.
    5.Corrosion-resistant terminals and enclosures; compact size, lightweight, and cabinet-compatible design for cost-effective installation.

  • Low Noise Dry-Type Iron Core Reactor

    1.Rated voltages:
    3kv,6kv,10kv,15kv,20kv,35kv
    2.Insulation: Class F.
    3.Uses epoxy resin casting or air insulation, eliminating fire and explosion hazards, making it ideal for indoor, subway, chemical plants, and other fire-sensitive environments.
    4.Typically consists of air-core coils (no iron core) or iron-core designs with air gaps, ensuring good magnetic linearity and avoiding saturation.

  • Filter Reactor

    7% reactance rate: Suppresses harmonics above the 5th order;
    14% reactance rate: Suppresses harmonics above the 3rd order.
    27% reactance rate: Suppresses harmonics above the 2nd order.
    1.Available in three-phase and single-phase dry-type iron-core configurations.
    2.Core: Imported cold-rolled silicon steel laminations segmented by epoxy-laminated glass spacers to stabilize air gaps.
    3.Windings: Tightly wound with Class H/C enamel-coated flat copper wire for high-temperature resistance and silent operation.
    4.Assembly: Non-magnetic fasteners; pre-baked, vacuum-impregnated, and thermally cured to bond core and windings, ensuring low losses and high harmonic suppression.
    5.Corrosion-resistant terminals and enclosures; compact size, lightweight, and cabinet-compatible design for cost-effective installation.

  • Dry-type Iron Core Reactor

    1.Rated voltages:
    3kv,6kv,10kv,15kv,20kv,35kv
    2.Insulation: Class F.
    3.Uses epoxy resin casting or air insulation, eliminating fire and explosion hazards, making it ideal for indoor, subway, chemical plants, and other fire-sensitive environments.
    4.Typically consists of air-core coils (no iron core) or iron-core designs with air gaps, ensuring good magnetic linearity and avoiding saturation.

  • Low Voltage Filter Reactor

    1.Rated voltages:
    3kv,6kv,10kv,15kv,20kv,35kv
    2.Insulation: Class F.
    3.Uses epoxy resin casting or air insulation, eliminating fire and explosion hazards, making it ideal for indoor, subway, chemical plants, and other fire-sensitive environments.
    4.Typically consists of air-core coils (no iron core) or iron-core designs with air gaps, ensuring good magnetic linearity and avoiding saturation.

  • Dry-Type Iron Core Shunt Reactor

    1.Rated voltages:
    3kv,6kv,10kv,15kv,20kv,35kv
    2.Insulation: Class F.
    3.Uses epoxy resin casting or air insulation, eliminating fire and explosion hazards, making it ideal for indoor, subway, chemical plants, and other fire-sensitive environments.
    4.Typically consists of air-core coils (no iron core) or iron-core designs with air gaps, ensuring good magnetic linearity and avoiding saturation.

  • Dry-Type Shunt Reactor

    1.Rated voltages:
    3kv,6kv,10kv,15kv,20kv,35kv
    2.Insulation: Class F.
    3.Uses epoxy resin casting or air insulation, eliminating fire and explosion hazards, making it ideal for indoor, subway, chemical plants, and other fire-sensitive environments.
    4.Typically consists of air-core coils (no iron core) or iron-core designs with air gaps, ensuring good magnetic linearity and avoiding saturation.

  • CKSC Dry-type Iron Core Series Reactor

    1.The coil is made of epoxy resin vacuum casting, after high temperature curing. 2.The coil insulation performance is good, high mechanical strength, the ability after glass fiber reinforcement is impacted by the large current shock and hot and cold cracks. 3.Moistureproof performance is good.

  • SVG Using Reactor

    1.Voltage Range:0.4kV,6V,10kV
    2.altitude:1000m or less
    3. the highest monthly average relative humidity: 95% or less
    4. the highest temperature: +45 °C
    5. the lowest ambient temperature: -10 °C
    6. the maximum daily temperature difference: 25 °C
    7. seismic intensity: 8 degrees
    8. installation requirements: indoor

  • CKSG Series Low Voltage Reactor

    7% reactance rate: Suppresses harmonics above the 5th order.
    14% reactance rate: Suppresses harmonics above the 3rd order.
    27% reactance rate: Suppresses harmonics above the 2nd order.
    1.Available in three-phase and single-phase dry-type iron-core configurations.
    2.Core: Imported cold-rolled silicon steel laminations segmented by epoxy-laminated glass spacers to stabilize air gaps.
    3.Windings: Tightly wound with Class H/C enamel-coated flat copper wire for high-temperature resistance and silent operation.
    4.Assembly: Non-magnetic fasteners; pre-baked, vacuum-impregnated, and thermally cured to bond core and windings, ensuring low losses and high harmonic suppression.
    5.Corrosion-resistant terminals and enclosures; compact size, lightweight, and cabinet-compatible design for cost-effective installation.

  • CKSC Dry-type Iron Core Reactor

    1.Rated voltages: 3kv,6kv,10kv,15kv,20kv,35kv
    2.Insulation: Class F.
    3.Uses epoxy resin casting or air insulation, eliminating fire and explosion hazards, making it ideal for indoor, subway, chemical plants, and other fire-sensitive environments
    4.Typically consists of air-core coils (no iron core) or iron-core designs with air gaps, ensuring good magnetic linearity and avoiding saturation

35