Home / Products

Products

0
  • 22kV capacitor bank for outdoor line compensation

    1.Integrated Design: Combines capacitor banks into a complete system.
    2.Reliable Protection: Comprehensive high/low-voltage protection ensures safe and reliable operation with minimal maintenance.
    3.Space-Saving & Cost-Effective: Compact footprint, reduced investment, short production cycle, and easy mobility.
    4.Flexible Configurations: Supports diverse electrical wiring schemes.
    5.Robust Structure:
    5.1Unique honeycomb-structured double-layer (composite panel) enclosure for enhanced durability, thermal insulation, and ventilation.
    5.2High ingress protection (IP) rating.
    5.3Material options: Stainless steel soft alloy, aluminum alloy, cold-rolled steel, or color-coated steel.

  • TBB10 High Voltage Reactive Power Automatic Compensation Device

    1.Rated voltage: 6–10kV
    2.Frequency: 50Hz
    3.Capacity: 100–10,000kVar
    4.Ambient temperature: -25℃ ~+45℃;
    5.Reactor options:
    Inrush suppression: 0.1–1% reactance
    5th+ harmonic suppression: 6% reactance
    3rd+ harmonic suppression: 12% reactance

  • GGJ Low Voltage Reactive Power Intelligent Compensation Device

    1.system voltage:Below AC450
    2.Automatic reactive power compensation to improve power factor
    3.Enhanced equipment efficiency with reduced investment costs
    4.Minimized distribution line losses and transformer losses
    5.Optimized voltage quality and improved power supply reliability
    6.Compatibility: Integrates with global cabinet systems (MNS/GCK/GGD)

  • XKGKL Dry-type Air Core Current Limiting Reactor

    XKGKL series dry-type air-core current limiting reactor in series connection in system line, increase the system impedance,the system failure limit short circuit current, the fault current dropped to permissible value.

  • BKGKL Dry-type Air Core Shunt Reactor

    1.Connected in parallel in 500 kv,200 kv and 110 kv substation low-voltage side, used for long distance transmission line
    2.capacitance reactive compensation, make the transmission and distribution system voltage stability.

  • CKGKL Dry-type Air Core Series Reactor

    1.Rated voltage:3464.1V
    2.Reactor connected in series with the capacitors suppress harmonic voltage amplification
    3. reduce system waveform distortion
    4.limit inrush currents during capacitor switching

  • CKSC Dry-type Iron Core Series Reactor

    1.The coil is made of epoxy resin vacuum casting, after high temperature curing. 2.The coil insulation performance is good, high mechanical strength, the ability after glass fiber reinforcement is impacted by the large current shock and hot and cold cracks. 3.Moistureproof performance is good.

  • SVG Using Reactor

    1.Voltage Range:0.4kV,6V,10kV
    2.altitude:1000m or less
    3. the highest monthly average relative humidity: 95% or less
    4. the highest temperature: +45 °C
    5. the lowest ambient temperature: -10 °C
    6. the maximum daily temperature difference: 25 °C
    7. seismic intensity: 8 degrees
    8. installation requirements: indoor

  • CKSG Series Low Voltage Reactor

    7% reactance rate: Suppresses harmonics above the 5th order.
    14% reactance rate: Suppresses harmonics above the 3rd order.
    27% reactance rate: Suppresses harmonics above the 2nd order.
    1.Available in three-phase and single-phase dry-type iron-core configurations.
    2.Core: Imported cold-rolled silicon steel laminations segmented by epoxy-laminated glass spacers to stabilize air gaps.
    3.Windings: Tightly wound with Class H/C enamel-coated flat copper wire for high-temperature resistance and silent operation.
    4.Assembly: Non-magnetic fasteners; pre-baked, vacuum-impregnated, and thermally cured to bond core and windings, ensuring low losses and high harmonic suppression.
    5.Corrosion-resistant terminals and enclosures; compact size, lightweight, and cabinet-compatible design for cost-effective installation.

  • CKSC Dry-type Iron Core Reactor

    1.Rated voltages: 3kv,6kv,10kv,15kv,20kv,35kv
    2.Insulation: Class F.
    3.Uses epoxy resin casting or air insulation, eliminating fire and explosion hazards, making it ideal for indoor, subway, chemical plants, and other fire-sensitive environments
    4.Typically consists of air-core coils (no iron core) or iron-core designs with air gaps, ensuring good magnetic linearity and avoiding saturation

  • Self-Healing Low-Voltage Filter Capacitors

    1.Uses metallized polypropylene film (MKP) as the dielectric. If a localized breakdown occurs, the surrounding metal layer evaporates instantly, restoring insulation and preventing failure 2.Encapsulated in epoxy resin or plastic housing, eliminating oil leakage risks and complying with environmental standards 3.rated voltage:440V, 480V, 525V, 690V 4.Rated Capacity: 5-100kvar(per unit)

  • 10KV 3 Phase Filter Capacitor

    1.rated voltage:10kv
    2.Frequency: 50/60Hz
    3.Operating: indoor or outdoor
    4.Ambient temperature: -40°C ~ +45°C
    ( Freezing field can meet - 45C)
    5.Wind load: not exceed 35m/s
    6.Altitude: not exceed 2000m
    7.Icing thickness: not exceed 10mm
    8.Seismic strength: 8
    9.Pollution level: III or IV

334