Reactors

0
  • CKSC Series Dry-Type Iron Core Reactor

    1.The coil is made of epoxy resin vacuum casting, after high temperature curing.
    2.The coil insulation performance is good, high mechanical strength, the ability after glass fiber reinforcement is impacted by the large current shock and hot and cold cracks.
    3.Moistureproof performance is good.

  • Iron Core Series Reactor

    1.The coil is made of epoxy resin vacuum casting, after high temperature curing.
    2.The coil insulation performance is good, high mechanical strength, the ability after glass fiber reinforcement is impacted by the large current shock and hot and cold cracks.
    3.Moistureproof performance is good.

  • Dry-type Series Reactor

    1.The coil is made of epoxy resin vacuum casting, after high temperature curing.
    2.The coil insulation performance is good, high mechanical strength, the ability after glass fiber reinforcement is impacted by the large current shock and hot and cold cracks.
    3.Moistureproof performance is good.

  • Series Reactor

    1.The coil is made of epoxy resin vacuum casting, after high temperature curing.
    2.The coil insulation performance is good, high mechanical strength, the ability after glass fiber reinforcement is impacted by the large current shock and hot and cold cracks.
    3.Moistureproof performance is good.

  • Iron Core Reactor for 10kV SVG

    1.Voltage Range:0.4kV,6V,10kV.
    2.altitude:1000m or less.
    3. the highest monthly average relative humidity: 95% or less.
    4. the highest temperature: +45 °C.
    5. the lowest ambient temperature: -10 °C.
    6. the maximum daily temperature difference: 25 °C.
    7. seismic intensity: 8 degrees.
    8. installation requirements: indoor.

  • Dry-type Iron Core Series Reactor

    1.The coil is made of epoxy resin vacuum casting, after high temperature curing.
    2.The coil insulation performance is good, high mechanical strength, the ability after glass fiber reinforcement is impacted by the large current shock and hot and cold cracks.
    3.Moistureproof performance is good.

  • SVG Line Reactor

    1.Voltage Range:0.4kV,6V,10kV.
    2.altitude:1000m or less.
    3. the highest monthly average relative humidity: 95% or less.
    4. the highest temperature: +45 °C.
    5. the lowest ambient temperature: -10 °C.
    6. the maximum daily temperature difference: 25 °C.
    7. seismic intensity: 8 degrees.
    8. installation requirements: indoor.

  • SVG Dedicated High-Performance Connection Reactor

    1.Voltage Range:0.4kV,6V,10kV.
    2.altitude:1000m or less.
    3. the highest monthly average relative humidity: 95% or less.
    4. the highest temperature: +45 °C.
    5. the lowest ambient temperature: -10 °C.
    6. the maximum daily temperature difference: 25 °C.
    7. seismic intensity: 8 degrees.
    8. installation requirements: indoor.

  • 10KV SVG Reactor

    1.Voltage Range:0.4kV,6V,10kV.
    2.altitude:1000m or less.
    3. the highest monthly average relative humidity: 95% or less.
    4. the highest temperature: +45 °C.
    5. the lowest ambient temperature: -10 °C.
    6. the maximum daily temperature difference: 25 °C.
    7. seismic intensity: 8 degrees.
    8. installation requirements: indoor.

  • SVG Connection Reactor

    1.Voltage Range:0.4kV,6V,10kV.
    2.altitude:1000m or less.
    3. the highest monthly average relative humidity: 95% or less.
    4. the highest temperature: +45 °C.
    5. the lowest ambient temperature: -10 °C.
    6. the maximum daily temperature difference: 25 °C.
    7. seismic intensity: 8 degrees.
    8. installation requirements: indoor.

  • SVG Reactor

    1.Voltage Range:0.4kV,6V,10kV.
    2.altitude:1000m or less.
    3. the highest monthly average relative humidity: 95% or less.
    4. the highest temperature: +45 °C.
    5. the lowest ambient temperature: -10 °C.
    6. the maximum daily temperature difference: 25 °C.
    7. seismic intensity: 8 degrees.
    8. installation requirements: indoor.

  • Low Noise Iron Core Reactor

    7% reactance rate: Suppresses harmonics above the 5th order;
    14% reactance rate: Suppresses harmonics above the 3rd order.
    27% reactance rate: Suppresses harmonics above the 2nd order.
    1.Available in three-phase and single-phase dry-type iron-core configurations.
    2.Core: Imported cold-rolled silicon steel laminations segmented by epoxy-laminated glass spacers to stabilize air gaps.
    3.Windings: Tightly wound with Class H/C enamel-coated flat copper wire for high-temperature resistance and silent operation.
    4.Assembly: Non-magnetic fasteners; pre-baked, vacuum-impregnated, and thermally cured to bond core and windings, ensuring low losses and high harmonic suppression.
    5.Corrosion-resistant terminals and enclosures; compact size, lightweight, and cabinet-compatible design for cost-effective installation.

67